we would enter an offset of +5 feet. Then in this example, the digital depth

 

would report a depth of 20 feet (from the surface) and the graphic image

 

scale range would shift from 0 to 20' to 5 to 25'.

Calibrate Water Speed

: Allows calibrating the value of Water Speed coming from the transducer.

 

The calibration value, in the range between -10% to +10%, will be applied to the water

 

speed from the transducer.

Calibrate Water Temp

: Allows the calibration on the Water Temperature sensor. Using the readings from a

 

precise temperature measuring device, insert a positive/negative offset to display the

 

correct temperature.

Calibrate Aux Temp

: Allows the calibration of the Aux Temperature sensor. Using the readings from a precise

 

temperature measuring device, insert here a positive/negative offset to display right

 

value on FF screens.

Set Default

: Restores the factory settings.

4.8ALARMS

The Alarms menu allows you to define alarm settings for Shallow Alarm, Depth Alarm and Temperature Upper/Lower/Rate. To set an Anchor Alarm, enter in a shallow water and depth value above and below your actual anchoring depth. The alarm will sound when the depth becomes shallower or deeper than the settings.

 

Figure 4.8 - Alarms sub-menu

 

 

Shallow Water

: Triggers an alarm when depth becomes shallower than the value set.

Depth Water

: Triggers an alarm when depth becomes deeper than the value set.

Fish

: The options for Fish Alarm set the size of the fishes that, if detected by the unit, switches an

 

alarm to sound. These options are: Off, Small, Medium, Big and Huge. The alarm sounds if

 

the set size (or bigger) is detected.

Temperature Upper

: Triggers an alarm when the transducer reports a temperature above the value set.

Temperature Lower

: Triggers an alarm when the transducer reports a temperature below the value set.

Temperature Rate

: Triggers an alarm when the transducer reports a temperature variation rate above the value set.

4.9LOAD SETTINGS FROM USER C-CARD

This option loads the complete set of Fish Finder settings from the User C-CARD (Memory card that may be used to backup the User Points and Tracks too).

4.10SAVE SETTINGS TO USER C-CARD

This option saves the complete set of Fish Finder settings to the User C-CARD.This is useful to avoid the user having to retune up Fish Finder after a Clear RAM operation or a software update.