7-6. Control Codes Used for Peripheral Units
FUNCTION
CODE
DEFINITION RANGE
OUTLINE
Adjust drive pulse width for peripheral unit 1
<ESC> <BEL> n1 n2 (1B)H (07)H n1 n2
1 n1 127, 1 n2 127 (default setting n1 = n2 = 20)
Adjusts drive pulse width for peripheral devices requiring other than standard 200 ms pulse time and delay time Energizing time = 10 × n1 (ms)
Delay time = 10 × n2 (ms) Executed by <BEL>, <FS> codes.
ON
OFF
|
| 10 × n1 (ms) |
|
| 10 × n2 (ms) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Printing and paper feed are prohibited.
NOTE
FUNCTION
CODE
OUTLINE
FUNCTION
CODE
OUTLINE
Adjustment is not necessary for standard cash drawers in the U.S.A. market.
Deferred drive command for peripheral unit 1
<BEL> (07)H
Executes drive pulse for peripheral unit 1 (deferred).
Immediate drive command for peripheral unit 1
<FS> (1C)H
Executes drive pulse for peripheral unit 1 (immediate). This code differs from the <BEL> code as follows:
When the printer receives an <FS> code, the command is executed immediately. The <BEL> code is stored in the data buffer in the same manner as other codes, and executed in the order in which they are received.
– 49 –