B-1. Parallel Interface Type

ON

OFF

No. 1 2 3 4 5 6 7 8

DIP-SW1

ON

OFF

No. 1 2 3 4

DIP-SW2

DIP-SW 1

Switch 1-1

Switch 1-2

Command emulation

ON

ON

Star Line Mode

OFF

ON

Star Page Mode

 

 

 

ON

OFF

DP8340 Mode

The factory settings of DIP switch are all on.

The functions of switches 1-3 through 1-8 will change according to the command emulation that has been set using switches 1-1 and 1-2.

(1) Star Line mode

Switch

Function

 

ON

OFF

 

 

 

 

 

 

 

 

 

1-1

Command emulation

 

Always ON

 

 

 

 

 

 

 

 

 

APPENDIX

1-2

Command emulation

 

Always ON

 

 

 

 

 

 

 

 

 

 

 

 

 

1-3

Should not be changed (Should be set to on)

 

 

 

 

 

 

 

 

 

 

 

1-4

Sensor adjustment

 

Invalid

Valid

 

 

 

 

 

 

 

 

 

1-5

Pin #31 (INIT) reset signal

 

Valid

Invalid

 

 

 

 

 

 

 

 

 

1-6

Handshaking conditions

 

Offline or receive

Receive buffer full

 

 

 

 

(conditions for BUSY)

 

buffer full

 

 

 

 

 

 

 

 

 

 

1-7

Automatic status back function

 

Invalid

Valid

 

 

 

 

 

 

 

 

 

1-8

Should not be changed (Should be set to on)

 

 

 

 

(2) Star Page mode

Switch

Function

 

ON

OFF

 

 

 

 

 

1-1

Command emulation

 

Always OFF

 

 

 

 

 

 

1-2

Command emulation

 

Always ON

 

 

 

 

 

 

1-3

Should not be changed (Should be set to on)

 

 

 

 

 

 

 

1-4

Sensor adjustment

 

Invalid

Valid

 

 

 

 

 

1-5

Pin #31 (INIT) reset signal

 

Valid

Invalid

 

 

 

 

 

1-6

Handshaking conditions

 

Offline or receive

Receive buffer full

 

(conditions for BUSY)

 

buffer full

 

 

 

 

 

 

1-7

Automatic status back function

 

Invalid

Valid

 

 

 

 

 

1-8

Should not be changed (Should be set to on)

 

 

– 102 –

Page 105
Image 105
Star Micronics TSP800 user manual Parallel Interface Type, Star Page mode