BASIC INSTALLATION & OPERATION

Combustion Air Requirements:

WARNING

Carbon Monoxide Warning

Water heater must be vented to outdoors.

Vent must be installed by a qualified technician using the local and state codes or, in the absence of local and state codes, the National Fuel Gas Code,

ANSI Z223.1 (NFPA 54) - current edition, and/or the installation instructions.

Examples of a qualified technican include: gas technicians, authorized gas company personel, and authorized service persons.

Failure to so do can result in death or carbon monoxide poisoning.

IMPORTANT: Air for combustion and ventilation must not come from a flammable or corrosive atmosphere. Any failure due to flammable or corrosive elements in the atmosphere is excluded from warranty coverage.

The following types of installation (not limited to the following) will require outdoor air for combustion due to chemical exposure and may reduce but not eliminate the presence of corrosive chemicals in the air:

beauty shops

photo processing labs

buildings with indoor pools

water heaters installed in laundry, hobby, or craft rooms

water heaters installed near chemical storage areas

water softeners

Combustion air must be free of acid-forming chemicals such as sulfur, fluorine, and chlorine. These elements are found in aerosol sprays, detergents, bleaches, cleaning solvents, air fresheners, paint, and varnish removers, refrigerants, and many other commercial and household products. When burned, vapors from these products form highly corrosive acid compounds. These products should not be stored or used near the water heater, air inlet, or air intake path.

Combustion and ventilation air requirements are determined by the location of the water heater. The water heater may be located in either an open (unconfined) area or in a confined area or small enclosure such as a closet or small room. Confined spaces are areas with less than 50 cubic feet for each 1,000 BTUH of the total input for all gas-using appliances.

Unconfined Space: A water heater in an unconfined space uses indoor air for combustion and requires at least 50 cubic feet for each 1,000 BTUH of the total input for all gas appliances. The table below shows a few examples of the minimum square footage (area) required for various BTUH inputs.

Table 1:

 

 

 

Minimum Square

Typical Room

BTUH Input

Feet with

with 8’ Ceiling

 

8’ Ceiling

 

 

30,000

188

9 x 21

45,000

281

14 x 20

60,000

375

15 x 25

75,000

469

15 x 31

90,000

563

20 x 28

105,000

657

20 x 33

120,000

750

25 x 30

135,000

844

28 x 30

IMPORTANT:

The area must be open and be able to provide the proper air requirements to the water heater. Areas that are being used for storage or contain large objects may not be suitable for water heater installation.

Water heaters installed in open spaces in buildings with unusually tight construction may still require outdoor air to function properly. In this situation, outside air openings should be sized the same as for a confined space.

Modern home construction usually requires supplying outside air into the water heater area.

Room exhaust fans may effect air requirements.

Confined Space: For the correct and proper operation of this water heater, ample air must be supplied for the combustion, ventilation, and dilution of flue gases. Small enclosures and confined areas must have two permanent openings so that sufficient fresh air can be drawn from outside of the enclosure. One opening shall be within 12 inches of the top and one within 12 inches of the bottom of the enclosure.

The size of each opening (free area) is determined by the total BTUH input of all gas utilization equipment (i.e., water heaters, furnaces, clothes dryers, etc.) and the method by which the air is provided. The BTUH input can be found on the water heater rating plate. Additional air can be provided by two methods:

1.All air from inside the building.

2.All air from outdoors.

12” MAXIMUM

 

 

 

CLOSET

 

 

 

PERMANENT

 

OR

 

OTHER

OPENINGS TO

 

CONFINED

THE OUTSIDE OR

 

SPACE

ADDITIONAL

 

 

ROOMS WITHIN

 

 

THE BUILDING

 

 

12” MAXIMUM

Figure 7

13

Page 13
Image 13
State Industries GS6, GSX, GPX manual Combustion Air Requirements, Carbon Monoxide Warning

GPX, GS6, GSX specifications

State Industries offers a range of high-quality residential and commercial water heaters that cater to diverse customer needs. Among their prominent models are the GSX, GS6, and GPX, each equipped with unique features, advanced technologies, and distinct characteristics that enhance their performance and efficiency.

The GSX series is well-known for its energy efficiency and reliability. It utilizes a high-efficiency gas burner to provide fast recovery rates, making it suitable for households with high hot water demand. The GSX water heaters are designed with a Foam Insulation System that minimizes heat loss and maximizes energy conservation. Additionally, their innovative design includes a durable glass-lined tank to prevent corrosion, ensuring long-term performance and extended lifespan.

Moving on to the GS6 model, this water heater is characterized by its user-friendly control features, including an adjustable thermostat that allows for precise temperature settings. The GS6 is built with a robust gas control valve that enhances efficiency and helps maintain consistent water temperature. The model is also designed with an anode rod that minimizes corrosion, prolonging the life of the tank. Its standing pilot light system provides reliable ignition, while its compact design makes it suitable for various installation locations, even in tight spaces.

The GPX series stands out in the market with its advanced technological features and sleek design. It integrates smart technologies designed to monitor and optimize performance. The built-in diagnostics programmable control allows users to track system performance and troubleshoot any potential issues easily. The GPX models also come equipped with a high-efficiency condensing gas burner that maximizes energy use, contributing to reduced utility bills. Furthermore, their stainless steel construction adds to their durability and resistance against rust and corrosion.

In summary, State Industries' GSX, GS6, and GPX models represent innovation in the water heating industry. They incorporate energy-efficient technologies, durable materials, and user-friendly controls, making them reliable choices for both residential and commercial applications. With custom features tailored to meet varied needs, these water heaters uphold State Industries' commitment to quality and customer satisfaction, ensuring that users enjoy consistent hot water while being conscious of energy consumption.