Display Settings

 

 

 

 

Description/Action

 

Display

 

Select Display Settings from the Main Menu and press the

 

Display Settings

 

Operational Button under "SELECT" to enter this menu. This

 

 

Temperature Units

°F

menu contains adjustable display options for viewing information

on the UIM’s LCD screen. Use the Up & Down Buttons to

Backlight Delay

30s

navigate the menu.

Contrast

 

60%

Temperature Units - Adjustable user setting that changes

 

 

 

 

 

temperature units display to Celsius °C or Fahrenheit °F.

 

 

 

Backlight Delay - Adjustable user setting that determines

 

 

 

 

how long the UIM’s LCD backlight remains illuminated after

 

 

 

 

a key has been pressed. Available settings are; Always Off,

CHANGE

BACK

HELP

 

10, 30 or 60 seconds and Always On.

Contrast - Adjustable user setting to adjust the UIM’s LCD screen contrast between text and background.

Note: These settings are adjusted in the same way described for the Operating Set Point And Differential Adjustment on page 47.

Heater Information

Description/Action

Display

Select Heater Information from the Main Menu and press the

Heater Information

Operational Button under "SELECT" to enter this menu. This

Elapsed Time

 

 

menu contains non adjustable operational information.

10 day 0 hrs 0 mins

Elapsed Time - Total accumulated time the control system

Burner On Time

 

(water heater) has been energized.

 

5 hrs 22 mins

Burner On Time - Total accumulated time the control

 

 

 

system has been in the heating operating state; burner run

Cycle Count

 

00000035

 

time.

CCB Version

 

X.XX

Cycle Count - Total accumulated count of heating cycles.

UIM Version

 

X.XX

CCB Version - Software version for central control board.

CHANGE

BACK

HELP

UIM Version - Software version for user interface module.

 

 

 

 

Note: Historical data is stored in the CCB's memory. If this

 

 

 

 

CCB is replaced during servicing the historical data on the

 

 

 

 

CCB being replaced will be lost. The data stored in the new

 

 

 

 

circuit board will no longer reflect the entire history of the

 

 

 

 

water heater.

 

 

 

 

The Elapsed Time, Burner On Time and Cycle Count indicate

 

 

 

 

age, usage and wear.

 

 

 

 

If the Cycle Count per day is high (divide cycle count by

 

 

 

 

days to determine cycles per day) or the cycle duration is

 

 

 

 

short (determine burner on time total minutes, divide burner

 

 

 

 

on time total minutes by cycle count) consider rasing the

 

 

 

 

Differential setting to avoid short cycling and excessive

 

 

 

 

component wear, see Operating Set Point And Differential

 

 

 

 

Adjustment on page 47.

 

 

 

 

This historical data can also be used to assist facilities

 

 

 

 

managers in forecasting planned replacement of equipment

 

 

 

 

to help avoid lengthy and costly hot water supply

 

 

 

 

interruptions.

 

 

 

47

Page 47
Image 47
State Industries SUF-130- 300/400/500 Display Settings Description/Action, Heater Information Description/Action Display