Connection of Emergency Stop Button

WARNING! Use caution when operating specific equipment to prevent electrical shock. Installation, service, alterations, and/or modifications must only be done by qualified personnel and with high regard for safety. Not conforming to the requirements could result in bodily harm, death, or costly damage.

NOTE: Alterations to the wiring diagrams require approval. Failure to do this will exclude all guarantee claims.

The wiring schematics are located in the control panel.

Connection of Emergency Stop Button

The machine may only be operated with installed Emergency Stop buttons. An Emergency Stop button must be installed at the control cabinet and at the grinding material in-feed if no Emergency Stop buttons have been installed at the factory.

NOTE: The control panel with the switches and Emergency Stop button must be installed near the machine. The distance should not exceed 5 m.

The distance between the floor and the lower edge of the control panel should be at least 1 m.

The connecting cables between the control panel and the machine must be protected against damage (cable tray, protective sleeve).

An additional Emergency Stop button has to be installed on the machine if the control box cannot be installed according to these rules.