7

Troubleshooting

 

 

 

 

 

 

Condition

Possible cause

Solution

 

Undersized connectors/lines.

Increase size of connectors/

 

water lines.

 

 

 

Long connecting lines between

Move the unit closer to the mold

 

unit and mold.

and shorten connecting lines.

 

Serpentine flow through mold.

Connect lines for parallel flow

 

instead of series flow.

 

 

 

Blocked line in mold.

Check mold for metal chips or

 

deposits. Clean mold.

Temperature fluctuations/rapid

 

Quick disconnect fitting with

Remove and replace fitting or

cycling from hot to cold.

check valve.

valve.

 

Carbon build-up in unit piping or

Clean or replace affected piping.

 

fittings.

Replace fluid.

 

 

Check unit by opening the

 

Faulty Sterlco TCU.

manual bypass to determine if

 

the TCU contols the set point

 

 

 

 

temperature.

 

Reversed probes.

Switch Return and Delivery

 

probes.

 

 

 

Loss of fluid in process.

Check all lines/connections/

 

fittings.

 

 

 

Vent valve open.

Allow vent timer to run out; or,

 

check valve operation when unit

Unit does not heat properly/can

 

is cold by opening the fill port.

 

Switch to Manual Cool mode

not achieve set point.

Faulty/dirty solenoid valve;

several times to flush valve. If

 

usually detected when there is a

the leak continues, disconnect

 

steady stream or trickle of water

the power to the unit, turn off the

 

out of the drain line.

water supply, and clean or

 

 

replace the solenoid.

 

Degraded fluid.

Drain and replace fluid.

 

 

Visual inspection of coil and

 

Defective heater contactor.

contacts. Repair/replace

 

 

defective contactors.

 

 

Check resistance on all three (3)

 

 

legs of heater with an

Unit does not heat.

Defective immersion heater.

ohmmeter. If not all equal,

 

contact factory for replacement

 

 

heater.

 

 

Check heater tank for scorched/

 

 

discolored paint. Check

 

Heater burnout.

resistance on all three (3) legs

 

 

of heater with an ohmmeter.

 

 

Replace heater as needed.