Servicing the Unit Monthly or Every 500 Hours

Lubricate the pump at the grease fittings with a high- quality polyurea grease rated at 320ºF or higher. Recommended: Chevron Black Pearl; do not over-lubricate.

Adjust the pump drive belt tension. Use the belt tensioning specifications listed in this chapter on Page 51. Make sure that the motor pulley is properly aligned with the pump pulley; use a straightedge to check. Tighten motor mounting bolts after realignment.

Inspect the screen in the Y strainer for accumulations of debris. Clean as needed.

Servicing the Unit Every Three Months

Remove and clean the screen in the Y-strainer. Replace the screen if it is damaged.