Identifying Process Air Temperature Controller LED Indicators

 

Indicator

Name

Description

 

 

 

 

 

 

 

PV

Process Value

During normal operation, the process value (PV)

 

 

 

 

Numeric LED

numeric LED indicator displays the process

 

8.8.8.8

 

 

 

 

temperature at the To Process thermocouple. It

 

 

 

 

 

also lists parameters during setup and error

 

 

 

 

 

messages if any errors occur.

 

 

 

 

 

SV

Set Value

During normal operation, the set value (SV)

 

 

 

 

Numeric LED

numeric LED indicator displays the process set

 

8.8.8.8

 

 

 

 

 

 

point temperature selected for the dryer. The dryer

 

 

 

 

 

 

 

 

 

 

then maintains this set point temperature. This

 

 

 

 

 

LED indicator also displays parameter and pre-set

 

 

 

 

 

function values during configuration setup.

 

 

 

 

 

OUT1

Out 1 LED

Lit when Control Output 1 is on. The Out1

 

 

 

 

 

indicator lights when the controller signals the

 

 

 

 

 

process heaters to be energized.

 

 

 

 

 

OUT2

Out 2 LED

Lit when Control Output 2 is on. Not used in

 

 

 

 

 

this application.

 

 

 

 

 

AT

AT LED

Flashes during auto-tuning in process value (PV)

 

 

 

 

 

screen.

 

 

 

 

 

 

 

 

 

Indicator

Name

Description

 

 

 

 

 

ALARM1

ALARM 1 LED

Lights in the Operation Indicator Section when

 

 

 

 

 

the output function assigned to auxiliary output

 

 

 

 

 

1 turns on. The ALARM1 indicator lights when

 

 

 

 

 

the process temperature falls below the set point

 

 

 

 

 

temperature by more than the alarm deviation

 

 

 

 

 

value. Advisory alarm does not interrupt operation

 

 

 

 

 

of the dryer.

 

 

 

 

 

 

 

 

 

Indicator

Name

Description

 

 

 

 

 

ALARM2

ALARM 2 LED

Lights in the Operation Indicator Section when

 

 

 

 

 

the output function assigned to auxiliary output

 

 

 

 

 

1 turns on. The ALARM2 indicator lights when

 

 

 

 

 

the process temperature exceeds the set point

 

 

 

 

 

temperature by more than the alarm deviation

 

 

 

 

 

value. Alarm output de-energizes the heaters.

 

 

 

 

 

Heaters re-energize when the temperature falls

 

 

 

 

 

within the acceptable range.

 

 

 

 

 

 