8-2 Technical Specifications

Annex B Information

The following design information is provided for your reference:

1.

No modifications are allowed to this equipment that could alter the CE compliance

2.

Ambient temperature:

0 degrees Celsius – Maximum (104 degrees Fahrenheit)

3.

Humidity range:

50% relative humidity

 

4.

Altitude:

Sea level

 

 

5.

Environment:

Clean, dust-free and non-explosive

6.

Radiation:

None

 

 

7.

Vibration:

Minimal, i.e. machine mounting

 

8.

Allowable voltage fluctuation:

+/- 10%

 

9.

Allowable frequency fluctuation:

Continuous

+/- 1%

 

 

 

Intermittent

+/- 2%

10.

Nominal supply voltage:

460/3/60 (Verify on serial number tag)

11.Earth ground type: TN (system has one point directly earthed through a protective conductor)

12.Power supply should include a ground connection.

13.Over-current protection is supplied in the dryer, but additional protection should be supplied by the user.

14.The door-mounted disconnect serves as the electrical disconnect device.

15.Dryer is not equipped with local lighting.

16.Functional identification

17.Dryer is equipped with a CE mark

18.Dryer is supplied with an operating manual in the language of the destination country.

19.Cable support may be required for power cord, depending on final installation.

20.No one is required to be in the interior of the electrical enclosure during the normal operation of the unit. Only skilled electricians should be inside the enclosure for maintenance.

21.Doors can be opened with a screwdriver, but no keys are required.

22.Two-hand control is not required or provided.

23.All dryers should be moved around and set in a place with a lift truck or equivalent.

24.There are no frequent repetitive cycles that require manual controlrepetitive functions are automatic while the dryer is operating.

25.An inspection report detailing the functional test is included with the dryer.

26.The machine is not equipped with cableless controls.

27.Color-coded (harmonized) power cord is sufficient for proper installation.

Aftercooler Design Specifications

 

Entering water temp.

ºF

 

ºC

85ºF

 

29ºC

Large Dehumidifying Dryers

Appendix

54

Page 54
Image 54
Sterling SDA 1000-5100 specifications Technical Specifications, Annex B Information, Aftercooler Design Specifications