Entering Operating Parameters to Select Modes
To enter the display:
1.Press the Mode Display key to view the Run/Stop & Alarm 1 Modes.
2.Press and to set the higher or lower the values of the parameter or turn that function On or Off.
The SV readout displays the different values for the parameter within a mode.
3.To switch modes within a level, press and hold the Level Display key for one (1) second.
The PV readout will display the different parameters within each mode.
4.Use short presses on the Mode Display key to display each parameter within a mode.
The SV readout displays the different values for the parameter within a mode.
5.Press and to set the higher or lower the values of a parameter or turn that function On or Off.
6.Press Level Key once to return to the Process Temperature Setting.
Figure 12: Settings for Process Temperature Controller (E5CN), Part No. A0555757
Mode | Parameter | Setting range | Default | Manuf. setting | |
Operation | Run/Stop | Run/Stop | Run | - | |
Alarm value 1 | 0 | 25 | |||
|
Mode | Parameter | Setting range | Default | Manuf. setting |
| AT execute/cancel | ON, OFF | OFF | ? |
Adjustment | Temperature input shift | 0.0 | - | |
Proportional Band | 0.1 to 999.9 | 8.0 | ? | |
| Integral Time | 0 to 3999 | 233 | ? |
| Derivative Time | 0 to 3999 | 40 | ? |
Large Dehumidifying Dryers | Controls | 31 |