PF - PROCESS FILTER

RF - REGEN FILTER

CV - CLOSED LOOP VALVE BV - BED SWITCH VALVE PS - PROCESS TEMP SWITCH RS - REGEN TEMP SWITCH PH - PROCESS HI TEMP

PL - PROCESS LOW TEMP RH - REGEN HI TEMP DP - DEWPOINT

PR - REDUNDANT SAFETY

ALARMS : PB RB

BV PS RS

PH PL RH

Screen 6.

5-4 Auto-Tuning the Dryer

1.For Auto-tuning, press the beige button once. The AT screen will show with the setting OFF.

2.Press the UP arrow to change the setting to ON.

3.Press the beige button again to go back to the Temperature Screen. Your actual temperature will start to flash for about 10-20 minutes with the temperature fluctuating up and down during that period. After the flashing stops, it means auto- tuning has finished.

5-5 Shutting Down the Dryer

1.Turn off the conveying system supplying the drying hopper.

2.When processing is complete, close the hopper slide gate and shut down any in-line companion equipment, such as the aftercooler.

3.Turn the Dryer OFF/ON/START selector switch to OFF.

4.Turn the system ON/OFF switch to OFF.

5.If needed, empty the drying hopper.

6.For maintenance or a long term shutdown, open (de-energize) the electrical disconnects at the dryer and at the power drop.

Large Dehumidifying Dryers

Operation

40

Page 40
Image 40
Sterling SDA 1000-5100 specifications Auto-Tuning the Dryer, Shutting Down the Dryer