2-4 Connecting the Compressed Air Supply

Before connecting the compressed air supply, check the following:

Check compressed air piping for correct installation and assembly.

Check the fittings, length and quality of the hose connections for agreement with requirements.

Check all compressed air lines for leakages.

You need a compressed air supply with 70-90 psi (5-6 bar) system pressure.

The air should be free of oil and water.

1.Find the compressed air hose, which has been supplied.

2.Connect it to the venturi assembly and to the control and maintenance unit.

3.The compressed-air hose is firmly pressed into each connecting socket.

4.Connect the control and maintenance unit to the compressed air supply. Max. input pressure 145 psi (10 bar) system pressure.

5.Set the pressure on the pressure reducer at 70-90 psi (5-6 bar).

Figure 3: Venturi Assembly

Maximum input pressure: 145 psi (10 bar) system overpressure.

Maximum output pressure: 90 psi (6 bar).

XSV-05, XSV-05/R, & XSV-05/2R Single Conveying Units - Venturi Style