5-4 Troubleshooting

PROBLEM

REMEDY (See Test Steps Below)

 

 

The unit is not conveying and is not

A, B, G, H

active.

 

 

 

The unit is not conveying; the

C, F

compressed air valve is switched

 

when the device is switched on.

 

 

 

The unit is not conveying; the

C, D, E, F, I, J, K

compressed air is flowing.

 

 

 

The unit is overfilled.

G, L, M

 

 

The unit is not filled properly.

C, D, E, F, I, J, K, L

 

 

Test steps:

Make sure the unit is switched ON.

Make sure the unit is plugged in and the proper voltage is present. Make sure sufficient compressed air is available 70-90 psi (5-6 bar). Make sure the venturi assembly is inserted in the material.

Make sure the compressed air hose is properly connected to the venturi assembly.

Make sure the compressed air hose is properly connected to the maintenance unit.

Make sure the level sensor is properly adjusted.

Make sure the cable of the level sensor is properly connected. Make sure the filter to is not clogged.

Make sure the screen is not clogged.

Make sure the conveyor vinyl flexible hose is properly connected. Make sure the compressed air supply is properly adjusted.

XSV-05, XSV-05/R, & XSV-05/2R Single Conveying Units - Venturi Style

25 of 36

Page 26
Image 26
Sterling SSV-05R, SSV-052R operating instructions Troubleshooting, Problem