Sterling STT 800 manual Dehumidified Air Dryer, Error and error correction, Valve Error Hopper

Models: STT 800

1 85
Download 85 pages 26.13 Kb
Page 44
Image 44
Temperature Measurement Granules Defective Hopper X

Dehumidified Air Dryer

Temperature Measurement Granules Defective Hopper X

(X = number of the drying hopper) Check cables and sensor.

Check the power supply.

Short circuit check.

Excess Temperature Granules Hopper X

(X = number of the drying hopper) The material temperature is too high.

Check the heater.

Check the throttle valve.

Valve Error Hopper X

(X = number of the drying hopper)

The throttle valve does not close or closes too slowly.

Check the throttle valve.

Temperature Measurement Pre Air Defective

Check cables and sensor.

Excess Temperature Pre Air

Check cables and sensor.

Check the pre air cooler.

Press the “F1"-key.

SM2-625

Error and error correction 4-9

Page 44
Image 44
Sterling STT 800 Dehumidified Air Dryer, Error and error correction, Temperature Measurement Granules Defective Hopper