Remove the protective grid of the blower (position 3).

STT 800

Blower ”regeneration heater” / Blower ”drying heater”

Remove the protective grid of the blower (position 3).

Loosen the nut (position 1).

Loosen and remove the screw (position 2).

Slide motor with carrier flange plate (position 6) towards the carrier flange housing (position 4). Remove defective V-belts (position 5), put on new ones.

F

Attention should be given to exact alignment of the V-belt pulleys.

Adjust belt tension by screw (position 2) in accordance with the information sticker. Tighten the nuts on threaded bolt (position 1) again.

Mount the protective grid of the blower (position 2).