Sterling STT 800 manual Maintenance, Return air filter

Models: STT 800

1 85
Download 85 pages 26.13 Kb
Page 49
Image 49
Return air filter

STT 800

Return air filter

Loosen the securing nut on the return air filter housing and remove the housing lid.

Remove the return air filter.

Clean the return air filter with compressed air from in- side to out or renew the filter. Never knock the return air filter on the floor.

Clean the return air filter housing. Use lint-free clea- ning rags.

Re-install the cleaned/new return air filter.

Mount the lid and fasten the securing nut.

Close the panel.

Regeneration air filter

Return air filter

Filter of the electrical cabinet

STT 800

F

&

Never operate the dryer without return air filter.

The dryer can’t be put into operation if the panel is not replaced.

Order number return air filter if operated

with return air cooler:

ID 88225

without return air cooler:

ID 86783

SM2-625

Maintenance 5-5

Page 49
Image 49
Sterling STT 800 manual Maintenance, Return air filter