Regeneration air filter

STT 800

Regeneration air filter

Loosen the securing nut on lid of the regeneration air filter.

Remove the lid and regeneration air filter housing.

Loosen the two wing nuts.

Remove the circular grid.

Remove the filter mat.

Blow through the filter mat with compressed air from the inside to the outside, or renew the filter. Re-install the cleaned/new filter.

Replace the circular grid.

Fasten the two wing nuts on.

Replace the regeneration air filter housing and the lid of the regeneration air filter. Fasten the securing nut onto the regeneration air filter.

Close the panel.

F

Never operate the dryer without regeneration air filter.

The dryer can’t be put into operation if the panel is not replaced.

&

Order number filter mat:

ID 93686

 

 

SM2-625

Maintenance 5-6