SKW-E

8.1. Installation

Installation is possible in any position.

The control system can be installed on the base plate or in a maximum distance of 3 m (9.84 ft.) from the unit. The control unit must be accessible at any time.

Install the SKW-E in such manner that differences in conveying distances for the two components are avoided.

Please note that the maximum ambient temperature near the SKW-E must not exceed +45°C (113°F).

Remove the plugs from the pipe bends.

Install the regrind line at intake port 1 (A).

Install the virgin material line at intake port 2 (B).

Install the feed line to the hopper loader at the outlet port (C).

Align both suction pipes nearly equally in order to avoid inaccurate percentage preselection re- sults.

A

B

C

SM3-641