Sterling Plumbing SKW-E manual Skw-E, Start-up, Significant zoning, Insignificant zoning

Models: SKW-E

1 42
Download 42 pages 1.49 Kb
Page 18
Image 18
Significant zoning.

SKW-E

a.) Setting 50 seconds = 1 switching cycle per conveying procedure

The SKW-E switches twice; it conveys regrind for 20 seconds and virgin material for 30 se- conds.

Significant zoning.

b.) Setting 10 = 5 switching cycles per conveying procedure

The SKW-E switches ten times; it conveys regrind for 4 seconds and virgin material for 6 seconds.

Insignificant zoning.

c.) Setting 5 = 10 switching cycles per conveying cycle

The SKW-E switches 20 times; it conveys re- grind for 2 seconds and virgin material for 3 seconds. This process is repeated 10 times.

No correct conveyance possible.

With a conveying time of 2 to 3 seconds the material cannot be conveyed properly.

SM3-641

Start-up 3-4

Page 18
Image 18
Sterling Plumbing SKW-E manual Skw-E, Start-up, Significant zoning, Insignificant zoning, No correct conveyance possible