INSTALLATION INSTRUCTIONS

SITE REQUIREMENTS

1.FLUE AND CHIMNEY REQUIREMENTS

1.1The chimney or flue system must comply with the rules in force.

1.2Fireplace opening up to 450mm (18") wide by 600mm (24") high will usually work with a 175mm (7") diameter flue. Larger openings will require bigger flues. See diagram 1 as a guide.

1

D

D

 

C

C

 

 

 

 

B

 

 

 

 

 

 

 

 

A

 

 

A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B

AR0596

 

 

 

 

AR0595

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

mm

mm

cm2

 

 

C

 

 

 

 

A

B

A x B

3.0m

4.5m

6.0m

9.0m

15.0m

 

 

350

550

1925cm2

175

175

175

175

175

 

 

400

550

2200cm2

175

175

175

175

175

 

 

460

460

2116cm2

175

175

175

175

175

 

 

460

550

2530cm2

200

175

175

175

175

 

 

460

610

2806cm2

200

200

175

175

175

 

 

610

460

2806cm2

200

200

175

175

175

 

 

610

610

3721cm2

250

225

200

200

175

 

 

610

760

4636cm2

300

250

250

225

200

 

 

760

460

3496cm2

225

225

200

200

175

 

 

760

610

4636cm2

250

250

250

225

200

 

 

760

760

5776cm2

300

300

250

250

225

 

 

760

910

6916cm2

350

300

300

250

250

 

 

910

460

4186cm2

250

225

225

200

200

 

 

910

610

5551cm2

300

300

250

250

225

 

 

910

760

6916cm2

350

300

300

250

250

 

 

910

910

8281cm2

350

350

300

300

250

 

 

910

1070

9737cm2

-

350

350

300

300

 

D

 

1070

460

4922cm2

300

250

250

225

200

 

 

1070

610

6527cm2

300

300

300

250

250

 

 

1070

760

8132cm2

350

350

300

300

250

 

 

1070

910

9737cm2

350

350

300

300

 

 

1070

1070

11449cm2

350

350

300

 

 

1070

1220

13054cm2

350

350

 

 

1220

460

5612cm2

300

300

250

250

225

 

 

1220

610

7442cm2

350

300

300

300

250

 

 

1220

760

9272cm2

350

350

300

300

 

 

1220

910

11102cm2

350

350

300

 

 

1220

1070

13054cm2

350

350

 

 

1220

1220

14884cm2

350

350

 

 

1520

460

6992cm2

300

300

300

250

250

 

 

1520

610

9272cm2

350

350

300

300

 

 

1520

760

11552cm2

350

350

300

 

 

1520

910

13831cm2

350

350

 

 

1520

1070

16264cm2

350

 

 

1520

1220

18544cm2

 

 

1.3The chimney or flue must be free from any obstruction. Any damper plates should be removed or secured in the fully open position, and no restrictor plates should be fitted.

1.4The chimney should be swept prior to the installation of the appliance - unless it can be seen to be clean and unobstructed throughout its entire length.

1.5Ensure that there is a smooth tapered transition from the fireplace opening into the chimney or flue.

1.6The flue pull should be checked prior to installation of the appliance. Apply a smoke pellet to the flue or chimney opening and ensure that the smoke is drawn into the opening. If there is not a definite flow, pre-heat the chimney for a few minutes and re-test the flow.

IF THERE IS STILL NO DEFINITE FLOW, THE CHIMNEY MAY REQUIRE ATTENTION - SEEK EXPERT ADVICE.

2.INSTALLATION OF THE GAS SUPPLY

2.1Before installation, ensure that the local distribution conditions (identification of the type of gas and pressure) and the adjustment of the appliance are compatible.

2.2Ensure that the gas supply is capable of delivering the required amount of gas, and is in accordance with the rules in force.

2.3Soft copper tubing and soft soldered joints can be used, but must not be closer than 50mm (2") to the base of the tray.

2.4A means of isolating the gas supply to the appliance must be provided independent of any appliance control.

2.5All supply gas pipes must be purged of any debris that may have entered prior to connection to the appliance.

3. VENTILATION

It is important to ensure that any national ventilation requirements are taken into account during the installation of this appliance.

3.1This appliance requires an air vent of at least 100cm2 effective area.

3.2It is essential to check for flue clearance, see installation section 6, Commissioning. If spillage is detected, it may be necessary to provide additional ventilation.

3.3The ventilation is in addition to any openable window, and although it must communicate with the outside air, wherever possible, it can communicate with an adjacent room provided that the space has a similar vent to the outside.

13

Page 13
Image 13
Stovax (P)8128**UC, (P)8120**UC Installation Instructions, Site Requirements, Flue and Chimney Requirements, Ventilation