Stow cs403026, cs 403016, cs403020, cs403030 operation manual Raise-Lower System Troubleshooting

Models: cs403030 cs403020 cs 403016 cs403026

1 62
Download 62 pages 21.38 Kb
Page 52
Image 52

STOW CS4030 SAW — MAINTENANCE

2

8

4

5

7 3

6

1

1.Pump Motor

2.Lift Pump Reservoir

3.Raise-LowerValve (Solenoid)

4.Raise-Lower Toggle

5.Raise-Lower Wire Harness

6.Lift Cylinder

7.Lift Pump Solenoid

Figure 62. Raise-Lower System

Raise-Lower System Troubleshooting

Refer to the following table to assist in troubleshooting the Raise-

Lower System.

Table 10. Raise-Lower System Troubleshooting

Indication

Possible Causes

 

 

Won't Raise

battery discharged, raise-lower solenoid faulty, cables

loose or damaged, defective wiring

 

Won't Lower

switch bad, faulty wiring connection, coil bad, valve

cartridge bad

 

PAGE 52 — STOW CS4030 SAW • OPERATION MANUAL — REV. #0 (12/13/07)

Page 52
Image 52
Stow cs403026, cs 403016, cs403020, cs403030 operation manual Raise-Lower System Troubleshooting