Sub-Zero ICBBI-36F BUILT-IN Insta LL Atio N Instru CTI on S, Elect Rica L Requ Irem Ents

Models: ICBBI-36RG ICBBI-36F ICBBI-36R

1 78
Download 78 pages 23.73 Kb
Page 7
Image 7

BUILT-IN INSTA LL ATIO N INSTRU CTI ON S

ELECT RICA L REQU IREM ENTS

A 220-240 V AC, 50/60 Hz, 10 amp circuit breaker and electrical supply are required. A separate circuit, servicing only this appliance, is required.

All Sub-Zero Built-In models are equipped with a power supply cord with a 3-prong grounding plug, which must be plugged into a mating

3-prong grounding-type wall receptacle. Follow local codes and ordinances when installing the receptacle. For location of the electrical supply, refer to the Installation Specifications illustration for your specific model on pages 4–6.

IMPORTANT NOTE: A ground fault circuit interrupter (GFCI) is not recommended and may cause interruption of operation.

WARNING

Do not use an extension cord or two-prong adapter. Electrical ground is required on this appliance. Do not remove the power supply cord ground prong.

CAUTION

The outlet must be checked by a qualified electrician to be sure that it is wired with the correct polarity. Verify that the outlet provides 220-240 V AC and is properly grounded.

WARNING

Always shut power off at the circuit breaker before performing any installation, service or maintenance.

IMPORTANT NOTE: The Built-In line is equipped with an appliance inlet type device. This allows easy replacement of the power cord. The appliance inlet is located on top of the unit on the compressor shroud. When replacing the power cord make sure that the replacement cord is rated HO5VV-F3G1.0 or equivalent to ensure safe operation of the appliance.

PLUMBIN G REQUIRE MENTS

IMPORTANT NOTE: A reverse osmosis system can be used, provided there is constant water pressure of 2.1 bar to 6.9 bar supplied to the unit at all times.

Rough in the cold water supply line using 6 mm OD copper line. The water line should be routed up through the floor within 13 mm from the back wall and no higher than 76 mm off the floor. If you have to come through the wall, make sure the water line is no more than 76 mm from the floor.

Regardless of the routing, allow .9 m of excess copper tubing to remain outside the wall or floor for easy connection to the unit. Locate the water supply line within the shaded area indicated in the Installation Specifications illustration for your specific model on pages 4–6.

Use an easily accessible shut-off valve between the water supply and the unit. Do not use self-piercing valves. A saddle valve kit (4200880) is available from your Sub-Zero dealer.

It is not recommended that the ice maker be connected to a softened water supply. Water softener chemicals, such as salt from a malfunc- tioning softener, can damage the ice maker and lead to poor ice quality. If a softened water supply cannot be avoided, be sure that the water softener is well maintained and operating properly.

IMPORTANT NOTE: All installations must meet local plumbing code requirements.

IMPORTANT NOTE: This appliance should be connected to a potable water supply.

UNPACK TH E UNIT

Uncrate the unit and inspect for any damages. Remove the wood base and discard the shipping bolts and brackets that hold the wood base to the bottom of the unit. Remove and discard all packing materials.

IMPORTANT NOTE: Do not discard the kick- plate, anti-tip bracket and hardware. These items will be needed for installation.

Retract the front leveling legs all the way up to allow the unit to be moved into position more easily. You will extend the leveling legs when the unit is in its final position to reduce the possibil- ity of the unit tipping forward.

IMPORTANT NOTE: The rear levelers must be in their lowest position in order to push the unit back into the rough opening. Therefore, leveling cannot be completed until the unit is in position.

Remove the drain pan from the base of the unit to avoid damage to the drain pan, and allow for proper placement of the appliance dolly.

WARNING

Be sure to secure the door(s) closed before moving the unit.

7

Page 7
Image 7
Sub-Zero ICBBI-36F BUILT-IN Insta LL Atio N Instru CTI on S, Elect Rica L Requ Irem Ents, Plumbin G Require Ments