Sub-Zero ICBBI-36R SI DE Panel in STA Llation, WO OD SID E Pane LS, Dual Instal Lation S

Models: ICBBI-36RG ICBBI-36F ICBBI-36R

1 78
Download 78 pages 23.73 Kb
Page 15
Image 15

SI DE PANEL IN STA LLATION

SI DE PANEL IN STA LLATION

IMPORTANT NOTE: Side panels will need to be installed before the unit is placed in its final position.

When installing a Built-In unit with side panels, an accessory side panel kit is necessary. A kit is available for installation of stainless steel side panels and one for installing custom wood side panels. Refer to the instructions with the stain- less steel side panel kit when installing stainless side panels. The following information is in refer- ence to installation of custom wood side panels.

WO OD SID E PANE LS

Routing will be necessary on the side panel in order for it to fit flush against the side of the unit. Refer to the illustration below for routing detail. If you have Model ICBBI-30U, ICBBI-30UG, ICBBI- 36U or ICBBI-36UG, extra routing will be neces- sary to avoid having the panel hit the refrigerator lower hinge plate. The illustration on the follow- ing page points out the areas where extra routing is needed for these models.

Install the brackets provided in the kit onto the side panel in the locations shown in the specifi- cations illustration below. The front brackets are meant to engage the mainframe and the back brackets will wrap behind the unit when the panel is in place. Screws are provided in the kit. If the provided screws will not work for your installation, you will need to provide the neces- sary screws to attach the brackets.

IMPORTANT NOTE: When a side panel is mounted on the hinge side of an over-and-under unit, it will be necessary to move the bottom front bracket down from the location shown in the illustration on the following page to avoid interfering with the hinge plate.

Place the panel at a 75° angle and engage the front brackets into the mainframe. Swing the panel inward, being sure that the front brackets engage the mainframe. With the panel in position, attach the rear brackets to the rear of the unit with the screws provided. Check to see that the panel is secure. Refer to the illustration below.

IMPORTANT NOTE: The use of side panels may change the width of your rough opening.

IMPORTANT NOTE: The overall height on the side panel will vary with the height of the grille being used. Make sure you know your finished height before cutting any panels.

DUAL INSTAL LATION S

When two Built-in units are installed side-by- side, it is necessary to use a Sub-Zero Built-in dual installation kit. Contact your Sub-Zero dealer for the proper components and installa- tion instructions.

IMPORTANT NOTE: Flush Inset panel sizes for dual installations are different than those listed in this book. Please refer to the Sub-Zero Built-In Refrigeration Design Guide.

IMPORTANT NOTE: Dual installations can only be accomplished using two units with opposite hinges.

610 mm

 

FRONT OF UNIT

 

25 mm

 

 

48 mm

3 mm

 

13 mm

 

Main

Side Panel

Frame

Routing

Front

 

Bracket

 

 

Side Panel

Rear

Main

Frame

Bracket

 

 

305 mm

 

146 mm

 

 

 

108 mm

2032

 

 

mm

2134

 

 

mm

 

 

 

1549

 

mm

1353

 

 

mm

 

 

5 mm DEEP

787

 

mm

 

HINGE SIDE

 

 

 

POCKET

 

 

32

521

 

mm

mm

 

25 mm

 

 

NO SIDE PANEL

 

102 mm

4 mm

67 mm

 

48 mm 25 mm

Routing detail— wood side panel

Side panel attachment—

 

top view

Side panel specifications

15

Page 15
Image 15
Sub-Zero ICBBI-36F, ICBBI-36RG SI DE Panel in STA Llation, WO OD SID E Pane LS, Dual Instal Lation S