8
Troubleshooting
Specs
Wiring Diagram
Rotor Assembly
Measuring Procedures
Safety Precautions
OIL Pressure Switch
Page 1
Image 1
SERVICE MANUAL
Models
RGV12100 / 13100T
GENERATORS
PUB-GS1328
Rev. 09/01
Page 1
Page 2
Page 1
Image 1
Page 1
Page 2
Contents
Generators
Contents
- 04-
- 1-
Specifications
- 2-
Performance Curves
- 3-
General Description of Generator
- 4-
Control Panel
- 5-
Serial Number
Stator
Construction and Function
- 6-
Brush / Brush Holder
Rotor
Current Transformer
Diode Unit RGV13100T only
ECU Electronic Control Unit
5 A.V.R Automatic Voltage Regulator RGV12100 only
- 8-
- 9-
Idle Control Unit RGV12100 only
AC Switch NO-FUSE Breaker
OIL Pressure Switch
Relief Valve
- 10-
RGV13100T
AC Receptacle
- 11-
AC plug Description
- 12-
Gfci Receptacle
Connecting to Domestic Circuit House Wiring
- 13-
- 14-
- 15-
- 16-
AC Three Phase Receptacle RGV13100T only
Primary Exciting Action RGV12100
Description of Generator Operation
Voltage Regulating Mechanism RGV12100
- 17-
Advantages of Current Transformer Control RGV13100T
Current Transformer Control RGV13100T
- 18-
Do not place inflammable materials near the generator
Safety Precautions
Operate the generator on a level surface
Do not operate with wet hands or in the rain
Range of Applications
Incandescent lamp, heater, etc. with a power factor
Motor driven tools and light electrical appliances
- 20-
- 21-
Appliances without any indication as to power consumption
- 22-
Measuring Instruments
Measuring Procedures
- 23-
- 24-
AC Output Measuring
Stator
Measuring Insulation Resistance
- 25-
Control Panel
Rotor
Current Transformer RGV13100T
- 26-
Pilot Lamp and Voltmeter
Checking Functional Members
AC Receptacles
- 27-
- 28-
RGV12100
Exciting Coil RGV12100 only
Rotor Assembly
- 29-
A.V.R
Brush
Automatic Voltage Regulator
- 30-
- 31-
Current Transformer RGV13100T only
RGV12100 only
Idle Control Unit
- 32-
- 33-
Preparation and Precautions
Disassembly and Assembly
Disassembly Procedures Control Panel
Alternator
- 35-
Component Parts
Generator assembly
Control Box RGV12100
Control Box RGV13100T
Fuel Tank
- 40-
Generator Assembling Procedures Front Cover
- 41-
- 42-
Rear Cover
- 43-
No AC output
Troubleshooting
AC Voltage is too high or too low Check engine speed
Check if engine is overheated
- 45-
Engine dose not run
- 46-
Wiring Diagram