* Checking table for analogue circuit tester.

Analogue circuit tester

 

Apply black - needle of the circuit tester

 

 

 

 

 

 

Yellow

Black 1

White 2

Light green 3

Brown 4 orYellow

 

 

 

 

 

 

 

 

 

 

 

 

Yellow

 

---------------

 

 

 

 

 

 

 

 

Apply red +

Black 1

 

---------------

200 kΩ

300 kΩ

 

 

 

 

 

 

 

needle of

White 2

 

60 kΩ

 

100 kΩ

the circuit

 

---------------

 

 

 

 

 

 

 

tester

Light green

3

16 kΩ

350 kΩ

125 kΩ

 

14 kΩ

 

---------------

 

Brown 4 orYellow

250 kΩ

100 kΩ

---------------

 

 

 

 

 

 

 

 

8-9 CURRENT TRANSFORMER (RGV13100T only)

Disconnect the connectors and couplers of current transformer.

Check the inter-terminal resistance of current transformer with a circuit tester.

Terminal number

1 and 2

1 and 3

2 and 3

 

 

 

 

RGV13100T

2.00Ω

2.00Ω

0.009Ω

 

 

 

 

If current transformer is found to be faulty, replace with new one.

8-10 ECU (ELECTRONIC CONTROL UNIT)

Check the resistance between 13 terminals of ECU with circuit tester.

1

2

3

4

5

6

13 12 11 10 9 8 7

Terminal number of the ELECTRONIC CON-

TROL UNIT

31

Page 34
Image 34
Subaru Robin Power Products RGV12100 service manual Current Transformer RGV13100T only, - 31-