8-3 AC SWITCH (NO-FUSE BREAKER)

Check continuity between each of 2 terminals at the back side of AC switch (no-fuse breaker) while it is mounted on the control panel.

Normally, there is continuity between each of the 2 terminals when the breaker is ON, while no continuity when the breaker is OFF.

RGV12100

8-4 STATOR

RGV13100T

Disengage connectors on the wires from stator and check the resistance between wires with a circuit tester, referring to the following specification table.

NOTE : If the circuit tester is not sufficiently accu- rate, it may not show the values given and may give erroneous readings.

Erroneous readings will also occur when there is a wide variation of resistance among coil windings or when measure- ment is performed at ambient tempera- tures different from 20

(68 °F).

 

 

 

 

Stator coil

 

 

Model

Hz/Voltage

 

 

 

 

 

Red-White

Black-Blue

Black-Red

White-

Black-White

 

 

 

 

Light green

 

 

 

 

 

 

 

 

 

 

 

 

 

RGV12100

60/120/240

0.11Ω

0.11Ω

------------

0.37Ω

------------

 

 

 

 

 

 

 

RGV13100T

60/120/208

0.23Ω

------------

0.23Ω

------------

0.23Ω

 

 

 

 

 

 

 

28

Page 31
Image 31
Subaru Robin Power Products 13100T service manual RGV12100, - 28-