4-2-8 OIL PRESSURE SWITCH

The oil pressure switch sends a signal to ECU to stop the engine when the engine oil pressure drops to 1.0 kg/cm2

4-2-9 RELIEF VALVE

The relief valve begins to open when the engine's oil pressure increases above 3.0 kg/cm2

OIL FILTER

CAMSHAFT

OIL PRESSURE SWITCH

RELIEF VALVE

CRANKSHAFT

OIL PUMP

OIL PUMP FILTER

4-2-10 AC SWITCH (NO-FUSE BREAKER)

The AC switch (no-fuse breaker) protects the generator from getting damage by overloading or short circuit in the appliance. The capacity of AC switch (no-fuse breaker) is as follows ;

Model

Specification

No-fuse Breaker

Object of Protection

 

 

 

 

RGV12100

60Hz-120V/240V

39A

Total output amperage

 

 

 

 

RGV13100T

60Hz-120V/208V

24A

Total output amperage

 

 

 

 