Function

Description of Operation

 

 

 

When the key switch or the remote control switch is turned to "START", the

 

fuel cut-off valve of the carburetor opens. When the key switch or the

 

remote control switch is turned to "STOP", the fuel cut-off valve closes.

 

 

 

If the starter motor is locked by any reason, the starter motor is shut off

 

automatically after 3 seconds.

 

 

Fail-safe function

When the engine dose not start (engine speed does not reach 1,050

r/min), the starter motor is stopped after 21 seconds.

 

 

 

 

When the remote controller is connected, the electric starter dose not run

 

when the switch of remote controller is turned "OFF" even if the key switch

 

on the generator is turned to "START".

 

 

 

When the engine speed increases higher than 4,500 r/min for 7 seconds,

 

the engine is shut down automatically and the warning lamp repeats turn-

 

ing on and off for 3 minutes.

 

 

Self checking function for

When the key switch or remote control switch is turned to "START", the

warning lamp lights up for a moment to indicate that the bulb for the warn-

warning lamp bulb

ing lamp is normal.

 

 

 

4-2-7 IDLE CONTROL UNIT (RGV12100 only)

The idle control unit 1 releases throttle valve when the applied load current exceeds 0.04A.

The two output wires 2 from the main coils must go through the ZCT 3 in the same direction.

NOTE :

It is normal that the engine speed goes up for a moment when you turn the key switch to "STOP" while the Idle Control Switch is in "ON" position.