Function | Description of Operation | |
|
| |
| When the key switch or the remote control switch is turned to "START", the | |
| fuel | |
| remote control switch is turned to "STOP", the fuel | |
|
| |
| If the starter motor is locked by any reason, the starter motor is shut off | |
| automatically after 3 seconds. | |
|
| |
When the engine dose not start (engine speed does not reach 1,050 | ||
r/min), the starter motor is stopped after 21 seconds. | ||
| ||
|
| |
| When the remote controller is connected, the electric starter dose not run | |
| when the switch of remote controller is turned "OFF" even if the key switch | |
| on the generator is turned to "START". | |
|
| |
| When the engine speed increases higher than 4,500 r/min for 7 seconds, | |
| the engine is shut down automatically and the warning lamp repeats turn- | |
| ing on and off for 3 minutes. | |
|
| |
Self checking function for | When the key switch or remote control switch is turned to "START", the | |
warning lamp lights up for a moment to indicate that the bulb for the warn- | ||
warning lamp bulb | ||
ing lamp is normal. | ||
| ||
|
|
4-2-7 IDLE CONTROL UNIT (RGV12100 only)
The idle control unit 1 releases throttle valve when the applied load current exceeds 0.04A.
The two output wires 2 from the main coils must go through the ZCT 3 in the same direction.
NOTE :
It is normal that the engine speed goes up for a moment when you turn the key switch to "STOP" while the Idle Control Switch is in "ON" position.