Summit 56214 Gas Instructions, m WARNING If there is a leak at connections 4, 5, 6 or, with water

Models: 56214

1 84
Download 84 pages 33.67 Kb
Page 12
Image 12
GAS INSTRUCTIONS

 

 

GAS INSTRUCTIONS

Check

 

A)

Bulkhead and gas supply hose connection (1)..

1

B)

Main gas line to manifold connections (2)..

C) Side burner hose to bulkhead connection (3)..

 

m WARNING: If there is a leak at connection (1, 2, or 3), retighten the fitting with a wrench and recheck for leaks with soap and water solution. If a leak persists after re-tightening the fitting, turn off the gas. DO NOT OPERATE THE GRILL. Contact the Customer Service Representative in your area using the contact information on our web site. Log onto www.weber.com®.

D) Side burner hose to quick disconnect connection, side burner valve and orifice connections (4)..

E) Regulator to cylinder connection (5).. F) Hose to regulator connection (6).. G) Valves to manifold connections (7)..

m WARNING: If there is a leak at connections (4, 5, 6 or 7),

 

turn off the gas. DO NOT OPERATE THE GRILL. Contact

 

the Customer Service Representative in your area using the

2

contact information on our web site. Log onto

 

www.weber.com®.

 

When leak checks are complete, turn gas supply off at the source and rinse connections

 

with water..

 

Reinstall Control Panel

 

Parts required: control panel, screws and burner control knobs..

A)Hook the top edge of the control panel onto the control panel brackets on either side of the front of the cookbox..

B)Line up screws with screw holes on both the control panel bracket and the frame..

C) Tighten screws..

D) Place corresponding control knobs onto the valve stems..

4

3

The grill illustrated may have slight differences than the model purchased.

5

6

7

12

Page 12
Image 12
Summit 56214 manual Gas Instructions, m WARNING If there is a leak at connections 4, 5, 6 or, with water