Sun Microsystems X4440, X4240 Handling Mismatching Processors, The BIOS performs a complete POST

Models: X4140 X4440 X4240

1 80
Download 80 pages 45.98 Kb
Page 73
Image 73
Handling Mismatching Processors

Handling Mismatching Processors

This section lists facts and considerations about how the server handles mismatching processors.

The BIOS performs a complete POST.

The BIOS displays a report of any mismatching CPUs, as shown in the following example:

AMIBIOS(C)2003 American Megatrends, Inc.

BIOS Date: 08/10/05 14:51:11 Ver: 08.00.10

CPU : AMD Opteron(tm) Processor 254, Speed : 2.4 GHz

Count : 3, CPU Revision, CPU0 : E4, CPU1 : E6

Microcode Revision, CPU0 : 0, CPU1 : 0

DRAM Clocking CPU0 = 400 MHz, CPU1 Core0/1 = 400 MHz Sun Fire Server, 1 AMD North Bridge, Rev E4

1 AMD North Bridge, Rev E6

1 AMD 8111 I/O Hub, Rev C2

2 AMD 8131 PCI-X Controllers, Rev B2

System Serial Number : 0505AMF028

BMC Firmware Revision : 1.00 Checking NVRAM..

Initializing USB Controllers .. Done.

Press F2 to run Setup (CTRL+E on Remote Keyboard)

Press F12 to boot from the network (CTRL+N on Remote Keyboard) Press F8 for BBS POPUP (CTRL+P on Remote Keyboard)

No SEL or DMI event is recorded.

The system enters Halt mode and the following message is displayed:

******** Warning: Bad Mix of Processors *********

Multiple core processors cannot be installed with single core processors.

Fatal Error... System Halted.

Appendix D Error Handling

63

Page 73
Image 73
Sun Microsystems X4440 Handling Mismatching Processors, The BIOS performs a complete POST, No SEL or DMI event is recorded