Sun Microsystems X4240, X4440, X4140 manual Handling of Parity Errors PERR

Models: X4140 X4440 X4240

1 80
Download 80 pages 45.98 Kb
Page 69
Image 69
Handling of Parity Errors (PERR)

Handling of Parity Errors (PERR)

This section lists facts and considerations about how the server handles parity errors (PERR).

The handling of parity errors works through NMIs.

During BIOS POST, the NMI is logged in the DMI and the SP SEL. See the following example command and output:

[root@d-mpk12-53-238 root]# ipmitool -H 129.146.53.95 -U root -P changeme -I lan

sel list -v

 

SEL Record ID

: 0100

Record Type

: 00

Timestamp

: 01/10/2002 20:16:16

Generator ID

: 0001

EvM Revision

: 04

Sensor Type

: Critical Interrupt

Sensor Number

: 00

Event Type

: Sensor-specific Discrete

Event Direction

: Assertion Event

Event Data

: 04ff00

Description

: PCI PERR

FIGURE D-3shows an example of a DMI log screen from BIOS Setup Page, with a parity error.

Appendix D Error Handling

59

Page 69
Image 69
Sun Microsystems X4240, X4440, X4140 manual Handling of Parity Errors PERR