Sun Microsystems X4140 Hardware Error Handling Summary Continued, Multiple fan, Fan failure is

Models: X4140 X4440 X4240

1 80
Download 80 pages 45.98 Kb
Page 77
Image 77
Hardware Error Handling Summary (Continued)

TABLE D-1

Hardware Error Handling Summary (Continued)

 

 

 

 

 

 

 

 

 

 

Logged (DMI

 

 

 

 

Log or SP

 

Error

Description

Handling

SEL)

Fatal?

 

 

 

 

 

Multiple fan

Fan failure is

The Front Fan Fault, Service Action Required,

SP SEL

Fatal

failure

detected by reading

and individual fan module LEDs are lit.

 

 

 

tach signals.

 

 

 

Single power

When any of the

supply failure

AC/DC

 

PS_VIN_GOOD or

 

PS_PWR_OK

 

signals are

 

deasserted.

Service Action Required, and Power Supply SP SEL

Non-fatal

Fault LEDs are lit.

 

DC/DC power

Any

The Service Action Required LED is lit, the

SP SEL

Fatal

converter

POWER_GOOD

system is powered down to standby power

 

 

failure

signal is deasserted

mode, and the Power LED enters standby

 

 

 

from the DC/DC

blink state.

 

 

 

converters.

 

 

 

Voltage

The SP monitors

The Service Action Required LED and Power

SP SEL

Fatal

above/below

system voltages and

Supply Fault LED blink.

 

 

threshold

detects voltage

 

 

 

 

above or below a

 

 

 

 

given threshold.

 

 

 

High

The SP monitors

The Service Action Required LED and System

SP SEL

Fatal

temperature

CPU and system

Overheat Fault LED blink. The motherboard

 

 

 

temperatures, and

is shut down above the specified critical level.

 

 

 

detects

 

 

 

 

temperatures above

 

 

 

 

a given threshold.

 

 

 

Processor

The CPU drives the

CPLD shuts down power to the CPU. The

SP SEL

Fatal

thermal trip

THERMTRIP_L

Service Action Required LED and System

 

 

 

signal upon

Overheat Fault LED blink.

 

 

 

detecting an

 

 

 

 

overtemp condition.

 

 

 

Boot device

The BIOS is not able

failure

to boot from a

 

device in the boot

 

device list.

The BIOS goes to the next boot device in the DMI Log

Non-fatal

list. If all devices in the list fail, an error

 

message is displayed, retry from beginning of

 

list. SP can control/change boot order.

 

Appendix D Error Handling

67

Page 77
Image 77
Sun Microsystems X4140, X4240, X4440 Hardware Error Handling Summary Continued, Multiple fan, Fan failure is, Sp Sel, Fatal