TABLE D-1

Hardware Error Handling Summary

(Continued)

 

 

 

 

 

 

 

 

 

Logged (DMI

 

 

 

 

Log or SP

 

Error

Description

Handling

SEL)

Fatal?

 

 

 

 

 

PCI SERR,

System or parity

PERR

error on a PCI bus.

BIOS POST

The BIOS could not

Microcode

find or load the

Error

CPU Microcode

 

Update to the CPU.

 

The message most

 

likely appears when

 

a new CPU is

 

installed in a

 

motherboard with

 

an outdated BIOS.

 

In this case, the

 

BIOS must be

 

updated.

Sync floods on HyperTransport links, the

DMI Log

Fatal

machine resets itself, and error information

SP SEL

 

gets retained through reset.

 

 

The BIOS reports, A Hyper Transport

 

 

sync flood error occurred on last

 

 

boot, press F1 to continue.

 

 

The BIOS displays an error message, logs the

DMI Log

Non-fatal

error to DMI, and boots.

 

 

BIOS POST

CMOS contents

The BIOS displays an error message, logs the

DMI Log

Non-fatal

CMOS

failed the

error to DMI, and boots.

 

 

Checksum Bad

Checksum check.

 

 

 

Unsupported

The BIOS supports

The BIOS displays an error message, logs the

DMI Log

Fatal

CPU

mismatched

error, and halts the system.

 

 

configuration

frequency and

 

 

 

 

steppings in CPU

 

 

 

 

configuration, but

 

 

 

 

some CPUs might

 

 

 

 

not be supported.

 

 

 

Correctable

The CPU detects a

The CPU corrects the error in hardware. No

DMI Log

Normal

error

variety of

interrupt or machine check is generated by

SP SEL

operation

 

correctable errors in

the hardware. The polling is triggered every

 

 

 

the MCi_STATUS

half second by SMI timer interrupts, and is

 

 

 

registers.

done by the BIOS SMI handler.

 

 

 

 

The SMI handler logs a message to the SP

 

 

 

 

SEL if the SEL is available, otherwise SMI

 

 

 

 

logs a message to DMI. The BIOS's polling

 

 

 

 

can be disabled through software SMI.

 

 

Single fan

Fan failure is

The Front Fan Fault, Service Action Required,

SP SEL

Non-fatal

failure

detected by reading

and individual fan module LEDs are lit.

 

 

 

tach signals.

 

 

 

 

 

 

 

 