Error Handling

A P P E N D I X D

Error Handling

This appendix contains information about how the servers process and log errors. See the following sections:

“Handling of Uncorrectable Errors” on page 53

“Handling of Correctable Errors” on page 56

“Handling of Parity Errors (PERR)” on page 59

“Handling of System Errors (SERR)” on page 61

“Handling Mismatching Processors” on page 63

“Hardware Error Handling Summary” on page 64

Handling of Uncorrectable Errors

This section lists facts and considerations about how the server handles uncorrectable errors.

Note – The BIOS ChipKill feature must be disabled if you are testing for failures of multiple bits within a DRAM (ChipKill corrects for the failure of a four-bit wide DRAM).

The BIOS logs the error to the SP system event log (SEL) through the board management controller (BMC).

The SP's SEL is updated with the failing DIMM pair's particular bank address.

The system reboots.

The BIOS logs the error in DMI.

53