From the ILOM web interface, select Reset on the Remote Power Control tab.

From the local server, press the Power button on the front panel of the server to power off the server, then press the Power button again to power-on server.

From the ILOM CLI on the server SP, type: reset /SYS

From the ILOM CLI on a CMM, type: reset /CH/BLn/SYS

Where n is the number of server module in chassis.

The BIOS screen appears.

3.When the Press F8 for BBS POPUP message appears on the BIOS POST screen, press F8 to select a boot device.

The Boot Device dialog appears.

Note – The dialog that appears in your installation may be different depending the type of disk controller installed in your server.

4.In the Boot Device dialog, select the menu item according to the Windows media installation method you elected to use and press Enter.

For example:

If you elected to use the Windows Local delivery method, select CD/DVDW.

If you elected to use the Sun ILOM Remote Console delivery method, select

Virtual CDROM.

5.When prompted with Press any key to boot from CD, press any key. The Windows installation wizard starts.

Continue the Windows installation wizard until the Installation Type dialog appears.

10 Sun Blade X6270 Server Module Windows Operating System Installation Guide • September 2009

Page 18
Image 18