SAS Enable/Disable (X8ST3-F Only)

SAS RAID Mode Select (X8ST3-F Only)A. RAID Enable2-32Manual backgroundManual backgroundManual backgroundX8ST3-F/X8STE User's Manual

SAS Enable/Disable (X8ST3-F Only)

JPS1 allows you to enable or disable SAS Connectors. The default position is on pins 1 and 2 to enable SAS. See the table on the right for jumper settings.

SAS RAID Mode Select (X8ST3-F Only)

JPS2 allows you to select the SAS RAID mode. You can use either Software RAID or IT Mode. Close this jumper to use Software RAID (Default). Set this jumper to open to use the IT Mode.

SAS Enable/Disable

Jumper Settings

Jumper Settings

Definition

 

 

Pins 1-2

 

Enabled (Default)

 

 

 

Pins 2-3

 

Disabled

 

 

 

 

 

Software RAID

 

 

Jumper Settings

 

 

 

Settings

 

Definition

Close

 

Software RAID Enabled (Default)

 

Open

 

IT Mode Enabled

 

 

 

 

 

KB/MOUSE

JPUSB1 JPW2

USB 0/1

 

IPMI LAN

COM1

 

LAN CTRL

 

 

for IPMIl LAN

SMBUS_PS1

DIMM3A

DIMM3B

DIMM2A

DIMM2B

DIMM1A

DIMM1B

Manual backgroundManual backgroundManual backgroundFAN1

JPW1

CPU FAN

A. RAID Enable

B.SAS RAID Mode Se- lect

VGA

LAN

CTRL1

 

LAN1

 

LAN2

 

LAN

 

CTRL2

 

FAN5

Intel Processor

Slot6 PCI-E 2.0 X8 on X16

Intel X58-Express

North Bridge

Battery

SPKR1

JBT1Manual background

JWOL Manual backgroundManual backgroundManual backgroundManual backgroundManual background

 

JLED

 

 

LE1

 

 

JF1

 

 

 

1

 

JOH

 

 

JWD

 

FAN2

 

 

JD1

T-SGPIO1

JAR

 

I-SATA1

I-SATA0

X8ST3-F/X8STE

SI/O

 

COM2

 

1

Slot5 PCI-E 2.0 X8

I-Button

Slot4 PCI-E 2.0 X4 on X8

BMC

Firmware

JPL1

 

 

 

JPL2

 

JPG1

 

Slot3 PCI-E 2.0 X8

 

 

 

 

BMC CTRL

Slot2 PCI 33MHz

 

WPCM 450

 

JBMC1

 

SAS0

Slot1 PCI 33MHz

 

JPUSB3

 

 

Floppy

JI2C1

JI2C2

 

BMC JTAG

USB2 USB3

 

 

 

 

 

BIOS

 

Intel ICH10R

 

 

 

South Bridge

 

 

 

SAS CTRL

 

 

 

LSI 1068E

 

 

3-SGPIO1

 

 

SAS1

SAS2

SAS3

SAS4

SAS5 LES2 SAS6

 

 

3-SGPIO2

 

 

 

 

JPS2

B

 

T-SGPIO2 I-SATA3

 

I-SATA2

 

I-SATA5

 

I-SATA4

 

USB 6/7

 

 

USB 4/5

 

JPUSB2

 

 

JPS1

JL1

A

 

1

LES1 FAN3

 

SAS7

 

 

 

FAN4

2-32

Page 56
Image 56
SUPER MICRO Computer X8STE user manual 2-32, SAS Enable/Disable X8ST3-F Only, SAS RAID Mode Select X8ST3-F Only