10-12
PPT 2700 Series Product Reference Guide
3. Continue to hold these buttons, including the battery door switch, until the IPL Baud
Rate menu displays:
If necessary, adjust the contrast by holding down the Function button and pressing
the up scroll button to darken the screen, or the down scroll button to lighten the
screen.
4. The version number on the top of the screen identifies the version of IPL you are
using. After the version number one of the following messages appears, indicating
why IPL was invoked:
IPL Key Sequence: IPL key sequence was pressed.
Partition Table not found: indicates no partition table was found.
Partition Table Checksum Error: indicates a checksum error was detected in the
partition table.
Use the up and down scroll buttons on the terminal to scroll to the appropriate baud
rate, then press the Action button to accept the selected baud rate. If no selection is
made within 10 seconds, the baud rate 115,200 is automatically selected.
IPL VER X.XX
IPL Key Sequence
-> 115,200
57,600
38,400
19,200
9600
Auto Baud
Press Up/Down to
select Baud Rate
Action to Continue