20-8
SPT 1700 Series Product Reference G uide
Digitizer Alignment Test
The Digitizer Alignment option tests the tracking of the stylus on the screen. To run this test,
tap the stylus in various places on the screen and crosshairs appear under the stylus. You
may also move the stylus continuously across the screen and the crosshai rs track the
movement of the stylus.
System Diagnostics Test
The System Diagnostics option is an interactive test of all the terminals system features.
This test prompts you to perform different actions and listen for different sound s. The output
of the system diagnostics is a log file.
To run system diagnostics tap the Start button. You are prompted to begin. Tap OK to start
the test.
The test prompts you to press the different buttons on the terminal. Pressing the spe cified
button results in a series of short high-pitched sounds, denoting prop er functioning.
Pressing an incorrect button or having the system timeout results i n a low tone, denoting
failure.
The test then produces a series of four tones to test the speakers and prompts you, asking
whether or not you heard all the tones. If you hear all four tones, answer Yes. If you dont
hear all the tones, answer No.
The test also prompts you to scan a bar code with the scanner. Press the OK button and
then scan an item.
System Diagnostics also performs some tests which are not i nteractive. It reads the system
information, tests the serial port, tests the memory, and tests the timer.
A series of tones denotes the conclusion of the test.
At this point, view the log file by tapping on View Log. This brings up the mul ti-page test
results log. You can scroll through the log, one page at a time, by tapping on the arrow
buttons in the lower left-hand corner of the screen. Alternately, use the scroll bar on the
right-hand side of the screen.