6 – Internal Settings and Operations
OPTIONS page
Make settings related to the
Moreover, when switching to Subfolder mode, the following
•• | When Folder mode is selected, the number of files created is |
| large. For this reason, the number of tracks that can be recorded |
| is greatly reduced. (See “Recording operation limitations” on |
| page 29.) |
•• | During recording, you can press the REC key to start recording a |
| new take. This function can be used 4 seconds after beginning |
| recording in Poly and Subfolder modes, but in Folder mode, you |
| might have to wait more than 4 seconds. |
Bit Length
Set the quantization bit rate for recording files. Setting buttons: 16bit, 24bit (default setting)
Max File Size
Set the maximum size for recording files. Setting buttons: 640MB, 1GB, 2GB (default setting)
Pause Mode
Set whether or not to divide files when a recording is paused.
Setting buttons: SPLIT (default setting), NOSPLIT
PreREC Time
Turn
When PreREC Time is ON, the signal input during recording standby is captured by the
To set the
Auto Marker
Make settings related to auto markers.
Audio Over: Use this to add markers when the set audio level is detected. Turn this function ON or OFF. (Default setting: OFF) and set the detection level (Default setting:
To set the audio detection level, touch the knob, and adjust the value using the DATA dial. The setting options are:
Settings made here are reflected in the Over Level setting on the METERSETUP screen.
Time Interval: Use this to add marks at fixed time intervals. Turn this function ON or OFF and set the time interval. (Default setting: OFF)
To set the time, touch the knob, and adjust the value using the DATA dial. The range of setting values is
Sync Unlock: Use this to add a mark when synchronization with the master clock is lost. Turn this function ON or OFF. (Default setting: OFF)
NOTE
An “audio over” occurs when the level exceeds the maximum level (full scale) minus the value set by the user. (In the example above, this would be when the level exceeds the maximum level minus 0.20 dB.)
44 TASCAM