6 – Internal Settings and Operations
Remote settings (REMOTE SETUP)
Make settings for PARALLE connector AUX
PARALLEL TAB
Set the AUX
AUX Assign
Touch a knob, making the background become yellow and turn the DATA dial to set the parameter. The parameters that can be selected include F.FWD, REW, MARK,
AUX1 Function: Set the function of PARALLEL connector pin 17 (AUX1). (Default setting: MARK SKIP +)
AUX2 Function: Set the function of PARALLEL connector pin 18 (AUX2). (Default setting: MARK SKIP
AUX3 Function: Set the function of PARALLEL connector pin 19 (AUX3). (Default setting: MARK)
RS-232C page
Make
Serial Mode
Set the serial connection mode with the following buttons.
Setting buttons:
NOTE
Baud Rate (bps)
Set the transmission speed. The options are 4800, 9600, 19200 and 38400 bps (default setting).
Data Length
Set the data length in bits. The options are 7 and 8 (default setting).
Parity Bit
Set whether or not there is a parity bit. The options are NONE (default setting), EVEN and ODD.
Stop Bit
Set the stop bit. The options are 1 (default setting) and 2.
RS-422 page
Make communication settings for
Serial Mode
Set the serial connection mode with the following buttons.
Setting buttons:
NOTE
The
Video Resolve
When slaving this unit to a VCR, video sync signals might be used instead of word sync signals for the common standard clock. In the same way as with word sync signals, you can select whether the video clock is followed (synchronizing the beginning of time code frames with video signal frame edges) or it is independent of the frame clock. This must be turned ON to control this unit from a video editor.
Setting buttons: “OFF”, “ON” (default value)
The
48 TASCAM