6Models 8752, 8756, 8757Safety
130819
SSupply cords used with this unit shall be
oil-resistant, sheathed flexible cable not
lighter than ordinary polychloroprene or other
equivalentsynt hetic elastomer-sheathed cord
(Code designation 60245 IEC 57) installed
with the proper cord anchorage to relieve
conductors from strain, including twisting, at
the terminals and protect the insulation of the
conductors from abrasion.
If the supply cord is damaged, it must be
replaced by the manufacturer, its service
agent,or s imilarly qualified person, in order to
avoid a hazard.
Failure to follow these instructions may result in
electrocution. Contact your local authorized Taylor
Distributor for service.
SDONOT allow untrained per sonnel to operate
this machine.
SDONOT operate t he freezer unless all service
panels and access doors are restrained with
screws.
SDO NOT remove any internal operating parts
(example: freezer door, beater, scraper
blades, etc.) unless all control switches are in
the OFF position.
Failureto follow thes e instructions may result in severe
personal injury from hazardous moving parts.
This unit has many sharp edges that can
cause severe injuries.
SDO NOT put objects or fingers in the door
spout. This may contaminate the product and
cause severe personal injury from blade
contact.
SUSE EXTREME CAUTION when removing
thebeater asssembly. The scraper bladesare
very sharp.
This freezer must be placed on a level
surface.F ailure to comply may result in personal injury
or equipment damage.
Access to the service area of the unit is
restricted to persons having knowledge and practical
experience with the appliance, in particular as far as
safety and hygiene are concerned.
Cleaning and sanitizing schedules are
governed by your state or local regulatory agencies
and must be followed accordingly. Please refer to the
cleaning section of this manual for the proper
procedure to clean this unit.
Thismac hine is designed to maintain product
temperature under 41_F(5_C). Any product being
added to this machine must be below 41_F(5_C).
Failure to follow this instruction may result in health
hazards and poor freezer performance.
DO NOT run the unit without product. Failure to follow
this instruction can result in damage to the unit.
DO NOT obstruct air intake and discharge openings:
Air cooled units require a minimum of 3” (76 mm) of
clearance around all sides of the freezer and 12” (305
mm) on top to allow for adequate air flow ac ross the
condenser(s).F ailure to allow adequate clearance can
reduce the refrigeration capacity of the freezer and
possiblycause permanent damageto the compress or.
ForIndoor Use Only: This unit is designed to operate
indoors, under normal ambient temperatures of 70_-
75_F(21_-24_C). The fr eezer has successfully
performed in high ambient temperatures of
104_(40_C) at reduced capacities.
NOISE LEVEL: Airborne noise emission does not
exceed 78 dB(A) when measured at a distance of 1.0
meter from the surface of the machine and at a height
of 1.6 meters from the floor.