35
Models 8752, 8756, 8757 Operating Procedures
Step 7
Using the long, flexible brush and the cleaning
solution, clean the mix inlet tube(s) located in the mix
cabinet. Thoroughly clean the tube(s) all the way up to
thefreezing c ylinder.T his area needs special attention
because bacteria and milkstone can build up here.
Step 8
Removethe rear dr ip pan from the side panel and take
it to the sink for cleaning.
Note: If the rear drip pan is filled wit h an excessive
amount of mix, refer to the Troubleshooting Guide.
Step 9
Thoroughly brush clean all disassembled parts in the
cleaningsolution, making sur e all lubricant and mix film
is removed. Take particular care to brush clean the
draw valve core(s) in the freezer door. Place all the
cleaned parts on a clean dry surface to air dry
overnight.
Step 10
Wipe clean all exterior surfaces of the freezer andthe
mix cabinet.
Check Topping Pump Temperatureand Volume - Model 8757
Tocheck the topping pump temperature and volume
ont he Model 8757 the following items will be needed:
SDigital thermometer with needle probe
Scalibratingcup
Sflatblade screwdriver
Ssanitizer (examples: Stera SheenRor
Kay-5R)
Note: This procedure should be performed on a
morning after the pumps were disassembled and
cleaned, on a monthly basis.
1. Dispense one serving of topping into a sundae
cup.
2. Insert the sanitized needle probe into the
topping. Let the probe stabilize for 20 seconds.
Note: Toppingtemperat ure should be between 115_
and 125_F(46_and 52_C) and must be this
temperature before pump calibration can begin. Water
bath temperature should be between 135_and 145_F
(57_and 63_C).
3. If the temperature is too cold or too warm, it
can be adjusted by the temperature control
located inside the machine, on the back of the
topping compartment.
4. Using the flatblade screwdriver, loosen and
remove the screws from the lower right panel.
Locate the adjustment screws, one for each
water bath.
5. Using a flatblade screwdriver, turn the
adjustment screwCLOCKWISE to INCREASE
and COUNTERCLOCKWISE to DECREASE
the water bath temperature. Adjust in small
increments.
6. Allow 10 minutes for the temperature to
stabilize in the water bath.
7. Check the temperature again in the water bath.
8. Place the topping pump back into the container.
9. Repeat these steps for the other topping. Install
the lower right panel, if applicable, and install
the screws.
10. Hold the small chamber of the calibrating cup
under the dispensing nozzle.
11. Pushthe dis pensing lever down for one full
stroke. The topping should be directed to the
bottom of the calibrating cup. Do not allow the
topping to fall on the sides of the cup.
Note: The amount of dispensed topping should be
one fluid ounce (29.6 ml).
12. If the dispensed amount is correct, proceed to
Step 13. If the amount of dispensed topping is
not correct, consult the Troubleshooting Section
of your Equipment Manual
13. Repeat Steps 10 through 12 for the other
topping pump, then proceed with Step 14.
14. Toppingpump temperatur e and volume check
is complete.