8757
042793-27
11/12/13
BRN
DRAW
SWITCH
BLK
RED
BLK
BRN RED
GRN/YEL
MIX HOPPER
TEMP
MEMBRANE
SWITCHES
BRN
BLK
GRN/YEL
BRN
BLK
BLK
MIX
LOW
MIX
SHK.TEMP/
VISCOSITY
COLDER
DIP SWITCH
UP = OFF
1-COMP 5
2-COMP 10
3-BTR 5
4-BTR 10
5-FAN 2
6-STBY DIS
7-INTERVAL
8-INTERVAL
SWITCH INTERVAL
7 8 TIME
OFF
OFF
ON
ON
OFF
ON
OFF
ON
16
14
11
5
MIX
OUT DRAW SHK
PUMP MIX 1 BRL
PROBE FAN MIX 2
SET POINT MIX LOW MIX OUT
STANDBY WASH AUTO PUMP
MIX
COLDER STANDBY
COLDER
LEFT LOGIC PANEL
SOFTECH CONTROL
MIX
LOW
MIX
SHK.TEMP/
VISCOSITY
COLDER
DIP SWITCH
UP = OFF
1-COMP 5
2-COMP 10
3-BTR 5
4-BTR 10
5-FAN 2
6-STBY DIS
7-INTERVAL
8-INTERVAL
SWITCH INTERVAL
7 8 TIME
OFF
OFF
ON
ON
OFF
ON
OFF
ON
16
14
11
5
MIX
OUT DRAW SHK
PUMP MIX 1 BRL
PROBE FAN MIX 2
SET POINT MIX LOW MIX OUT
STANDBY WASH AUTO PUMP
MIX
COLDER STANDBY
COLDER
RIGHT LOGIC PANEL
SOFTECH CONTROL
MEMBRANE
SWITCHES
MIX LEVEL
PROBE
STANDBY
TEMP
WHT
GRN/YEL
DRAW
SWITCH
BLK
RED
BRN
BRN
BLK
BRN
BLK
MIX LEVEL
PROBE
STANDBY
TEMP
WHT
GRN/YEL
GRN/YEL
POWER
SWITCH
4PDT
GRN/YEL
FUSE
BLKBLK
BLK
BLK/WHT
BLK
BLK
BLK
BLK
H.P.SW.
M
BEATER
MTR.
(FIGURE 2) WHT
COMP
(FIGURE 3)
M
MM
M
M
M
M
YEL
RED
CNO L2 BEATER 0L L1
MIXFANPUMP
BTR
COM
BRN
BLK
YEL
ORN
RED
LEFT
POWER/RELAY
BOARD
BLK
WHT
BLK
BLK
BLK
BLK/WHT
BLU/WHT
BLU
BLK/WHT
BLK/WHT
MIX CAB.
EVAP. FANS
WHT
BLK/WHT STRIPE
ORN
BLK
BLK
WHT
FAN RELAY
(AIR COOLED ONLY) WHT
BLK
CORDRED BLK
CORD
MIX CAB.COND.FAN
(WATER COOLED ONLY)
WHT
BLK WHT
MIX CAB
COMP.
OLVO
WHT
START
REALY
I
MS
RS C
BRN
CONDENSOR BLOWER (AIR COOLED
ONLY) SEE FIG 1
L1 L2
LINE
BLU
BLU
FUSE
WHT
BLK
BLK
ORN
BLK
CNO L2 BEATER 0L L1
MIXFANPUMP
BTR
COM
RIGHT
POWER/RELAY
BOARD
RED
ORN
YEL
BLK
BLK
BLK
H.P.SW
BLK
BEATER
MTR.
(FIGURE 2)
COMP
(FIGURE 3)
BLK
BLK
L1 L2
WHT
4
3
2
YEL
WHT
BLU
RED
BLK
PUMP ROTATION
AS VIEWED
FROM FRONT
OVLD.
RESET
RED
BLK
WHT
BLK
BLK
BLK
BLU/WHT
NC NO
C
NC NO
C
MIX
PUMP
HEATER
SWITCH
BLK
THERMOSTAT HI LIMT
TERMOSTAT
SYRUP
HEATER
WHT
WHT FUSE
WHT
BRN
WHT WHT
40 WATT
HEATER
CONDENSATION PAN
HEATER OPTION
IN PHANTOM
WHT FUSE
BLK
BLK
LINE
WHT
BLU/WHT
BLU
BLU
BLK
BLK
GRN/YEL

GROUND FRAME

SECURELY

GRN/YEL
GRN/YEL
GRN/YEL
GRN/YEL
GRN/YEL
GRN/YEL
GRN/YEL
GRN/YEL
BLK
BLK
12V
230V
BLK
YEL
BRN
ORN
YEL
BRN
ORN
BLK
TEMP. INDICATOR
TRANS.
TEMP. INDICATOR
TRANS.
MTS CABINATE TEMP.
INDIACTOR.
DIGITAL TEMP. INDICATOR
OPTION IN PHANTOM.
S
R
LINE
RELAY
START CAPACITOR
C
INTERNAL OVERLOAD
RUN CAPACITOR
SCHEMATIC WIRING DIAGRAM - CSR
1
2
5
4
WHT
BRN
BLK
BRN
052396-1
EQUIPMENT
GROUND
BLEED RESISTOR
WHT(120 VOLTS; 220V-50Hz)
BLK(230 VOLTS)
BLK
BLU
1
2
4
6
BLK
BLK
BLK
T1
CP
T2
L1
CP
L2
BEATER MOTOR
CONTACTOR
MAGNETEK BEATER MOTOR WIRING
STEPS:
1) REMOVE BROWN JUMPER FROM BETWEEN TERMINAL #1 TO TERMINAL #5
2) MOVE BLUE INTERNAL (FROM MOTOR MAIN WINDING)
FROM TERMINAL #5 TO TERMINAL #1.
NOTE: FOR CCWLE - BLUE INTERNAL ON #1, YELLOW INTERNAL ON #6
BLU INTERNAL
3
5
ORN INTERNAL
RED INTERNAL
YEL INTERNAL
BLK INTERNAL
BLK
1
2
3
4
T8
T1
T7
T4
T5
BLK
BLU
BLK
T1
CP
T2
L1
CP
L2
BEATER MOTOR
CONTACTOR
LEESON BEATER MOTOR WIRING
STEPS:
1) DISCONNECT WIRE T7 FROM TERMINAL 3
2) SPLICE BLUE WIRE AS SHOWN
BLU
USE T3 AND L3 WHEN
CP CONTACTS ARE NOT AVAILABLE
START
13
MAIN
2
4
2C
THERMAL
O.L.
EXTRA
MAIN
65
RED 50 HZ
BLK 60 HZ
WHT COM
BRN
BRN
CAP
208/240 50/60 HZ
GE MOTOR SCHEMATIC
FIG 1
BLACK
BLUE
BLACK
T1
CP
T2
L1
CP
L2
BEATER MOTOR
CONTACTOR
GE/RBC BEATER MOTOR WIRING
NOTE: FOR CCWLE - BLUE INTERNAL ON #1,YELLOW INTERNAL ON #2
BLUE
T3 L3
USE T3 AND L3 WHEN CP
CONTACTS ARE NOT AVAILABLE
J12 OR PURPLE INTERNAL
T1 OR BLUE INTERNAL
T8 OR RED INTERNAL
J9 OR BLACK INTERNAL A
14
5
T4 OR YELLOW INTERNAL
2
FIG 2 FIG 3
BLK
BLK
BLK
BLK
BLK
BLK
M
BLK BLK
PRESSURE
SW. 24VAC
26
48
37
BLK
M
BLK BLK
PRESSURE
SW.
WHT
4
3
2
YEL
WHT
BLU
RED
BLK
PUMP ROTATION
AS VIEWED
FROM FRONT
OVLD.
RESET
MIX
PUMP
24VAC
26
48
37
BLK
MIX PUMPFIG 4 ALTERNATE WIRINGDIAGRAM
MOTOR
CCW LINE
PRP
WHT
BLK
OVLD.
RELAY
3
24
BLK
WHT
L1
L2 DR N
(SEE FIGURE 4)
(SEE FIGURE 4)
B
B
A
A
B
B
A
A
8
5
12
9
4
113
14
N. O.
DOOR
INTERLOCK
SWITCH
BLK
24VAC
YEL
YEL
BLK/WHT
BLK/WHT
BLU/WHT
BLU/WHT
BLK/WHT
WHT
BLK
PUR/WHT
WHT
WHT WHT
WHT