8757
042793-3311/12/13
BRN
DRAW
SWITCH
BLK
RED
BLK
BRN RED
GRN/YEL
MIX HOPPER
TEMP
MEMBRANE
SWITCHES
BRN
BLK
GRN/YEL
BRN
BLK
BLK
MIX
LOW
MIX
SHK.TEMP/
VISCOSITY
COLDER
DIP SWITCH
UP = OFF
1-COMP 5
2-COMP 10
3-BTR 5
4-BTR 10
5-FAN 2
6-STBY DIS
7-INTERVAL
8-INTERVAL
SWITCH INTERVAL
7 8 TIME
OFF
OFF
ON
ON
OFF
ON
OFF
ON
16
14
11
5
MIX
OUT DRAW SHK
PUMP MIX 1 BRL
PROBE FAN MIX 2
SET POINT MIX LOW MIX OUT
STANDBY WASH AUTO PUMP
MIX
COLDER STANDBY
COLDER
LEFT LOGIC PANEL
SOFTECH CONTROL
MIX
LOW
MIX
SHK.TEMP/
VISCOSITY
COLDER
DIP SWITCH
UP = OFF
1-COMP 5
2-COMP 10
3-BTR 5
4-BTR 10
5-FAN 2
6-STBY DIS
7-INTERVAL
8-INTERVAL
SWITCH INTERVAL
7 8 TIME
OFF
OFF
ON
ON
OFF
ON
OFF
ON
16
14
11
5
MIX
OUT DRAW SHK
PUMP MIX 1 BRL
PROBE FAN MIX 2
SET POINT MIX LOW MIX OUT
STANDBY WASH AUTO PUMP
MIX
COLDER STANDBY
COLDER
RIGHT LOGIC PANEL
SOFTECH CONTROL
MEMBRANE
SWITCHES
MIX LEVEL
PROBE
STANDBY
TEMP
WHT
GRN/YEL
DRAW
SWITCH
BLK
RED
BRN
BRN
BLK
BRN
BLK
MIX LEVEL
PROBE
STANDBY
TEMP
WHT
GRN/YEL
GRN/YEL
POWER
SWITCH
4PDT
GRN/YEL
FUSE
BLKBLK
BLK
BLK
BLK/WHT
BLK
BLK
BLK
BLK
H.P.SW.
M
BEATER
MTR.
WHT
COMP.
M
M
M
M
M
M
GRN/YEL
YEL
RED
CNO L2 BEATER 0L L1
MIXFANPUMP
BTR
COM
BRN
BLK
YEL
ORN
RED
LEFT
POWER/RELAY
BOARD
BLK
WHT
BLK
BLK
BLK
BLK/WHT
BLU/WHT
BLU
BLK/WHT
BLK/WHT
MIX CAB.
EVAP. FANS
WHT
BLK/WHT
ORN
BLK
BLK
BLK
WHT
FAN RELAY
(AIR COOLED ONLY) WHT
BLK
CORDRED BLK
CORD
MIX CAB.COND.FAN
(WATER COOLED ONLY)
WHT
BLK WHT
MIX CAB
COMP.
OLVO
WHT
START
REALY
I
MS
RS C
BRN
CONDENSOR BLOWER
(AIR COOLED ONLY)
(SEE FIG 1)
L1 L2 L3
LINE
BLU
BLU
FUSE
WHT
BLK
BLK
ORN
BLK
CNO L2 BEATER 0L L1
MIXFANPUMP
BTR
COM
RIGHT
POWER/RELAY
BOARD
RED
ORN
YEL
BLU/WHT
BLK
BLK
BLK
H.P.SW
BLK
BEATER
MTR.
COMP
BLK
BLK
BLK
L1 L2 L3
RED
BLK
WHT
BLK
BLK
BLK
BLU/WHT
NC NO
C
NC NO
C
WHT
GROUND FRAME
SECURELY
BLK
WHT
BLK
BLU
BLU/WHT
GRN/YEL LINE
GRN/YEL
GRN/YEL
GRN/YEL
GRN/YEL
GRN/YEL
GRN/YEL
GRN/YEL
GRN/YEL
BLK
BLK
BLK
BLK
BLK
BLK
BLK
BLK
12V
230V
BLK
YEL
BRN
ORN
YEL
BRN
ORN
BLK
TEMP. INDICATOR
TRANS.
TEMP. INDICATOR
TRANS.
MTS CABINATE TEMP.
INDIACTOR.
DIGITAL TEMP. INDICATOR
OPTION IN PHANTOM.
L2 FUSE
BRN
WHT WHT
40 WATT
HEATER
CONDENSATION PAN
HEATER OPTION
IN PHANTOM
BLK
BLK
BLK
M
GRN/YEL
M
BLK BLK
PRESSURE
SW.
WHT
4
3
2
YEL
WHT
BLU
RED
BLK
PUMP ROTATION
AS VIEWED
FROM FRONT
OVLD.
RESET
MIX
PUMP
24VAC
2 64837BLK
M
BLK BLK
PRESSURE
SW.
WHT
4
3
2
YEL
WHT
BLU
RED
BLK
PUMP ROTATION
AS VIEWED
FROM FRONT
OVLD.
RESET
MIX
PUMP
24VAC
264837BLK
GRN/YEL
L2 FUSE
GROUND FRAME
SECURELY
(SEE FIG 2)
(SEE FIG 2)
B
B
A
A
B
B
A
A
START
13
MAIN
2
4
2C
THERMAL
O.L.
EXTRA
MAIN
65
RED 50 HZ
BLK 60 HZ
WHT COM
BRN
BRN
CAP
208/240 50/60 HZ
GE MOTOR SCHEMATIC
FIG 1
BLK
WHT
YEL
YEL
BLK/WHT
WHT
8512 9411314N. O.DOORINTERLOCKSWITCHBLK PUR/WHTBLU/WHTBLU/WHTBLK/WHTBLK/WHTMIX PUMP
FIG 2
ALTERNATE WIRINGDIAGRAMMOTORCCW LINE
PRP
WHT
BLK
OVLD.
RELAY
3
24
BLK
WHT
L1
L2 DR N
HEATER
SWITCH
BLK
THERMOSTAT HI LIMT
TERMOSTAT
SYRUP
HEATER
WHT WHT WHT