Model 8752
037808-40
04/14
Taylor Company
2014 Carrier Commercial Refrigeration, Inc.
c
GRN/YEL
BLK
BLK BLK/WHT
GND
L2L1
OL
COMP BTR PUMP FAN MIXA1 A2
BTR.
CONTACTOR
M
A1 A2
COMP.
CONTACTORCOMP
L1 N
14T3
T2
T1L1
L2
L3
13L1
L2
L3
13 14T3
T2
T1

B B

POWER
SWITCH
2PDT
POWER/RELAY BOARD
GRN/YEL
WHT
BLK/WHT
ORN
RED/BLK
WHT
WHT
WHT
WHT
BLK/WHT
BLKWHT
BLK
ORN
RED/BLK
BRN
YEL
HIGH PRESS.CUTOUTBEATER MOTOROVERLOAD SWITCH
MIX
LOW MIX
OUT
MIX STANDBY
MAX
MIN
MAX
MIN
MAX
MIN
MFG DATE
MIX LOW MIX OUT
MIX STANDBY WASH AUTO PUMP
DRAW PUMP
SOFTECH CONTROL
TAYLOR CO.
42002
MIX 1 BRL
PROBE
SET POINT
S.S.VISCOSITY
SHAKE TEMP.
FAN MIX 2
DIP SWITCH
UP = OFF
1-COMP 5
2-COMP 10
3-BTR 5
4-BTR 10
5-FAN 2
6-STBY DIS
7-INTERVAL
8-INTERVAL
SHK
SWITCH INTERVAL
78 TIME
OFF
OFF
ON
ON
OFF
ON
OFF
ON
16
14
11
5
BRN
RED
BRN
BLK
WHT
B
B
STBY TEMP.
(SEE NOTE 1)
96 95
BLK
BLK
YELBLK
MIX HOPPER
TEMP.
BLK
L2 FUSEL1 FUSEC
DRAW
SWITCH
NC NO
BLK/WHT
M
MIX EVAP FANS
M
M
MIX COND. FAN
M
FAN - (A/C & W/C)
BLK
BRN
BLK WHT
WHT
BEATERL1
L2
L3
T1CP
T2
WHT
BLK
BLK
BLU
BLK
BLU
OVERLOAD RESET
BLK
BLK
WHT
WHT
BTR
BLK
BLK
BLK
BLK
GRN/YEL
BRN
CAPACITORUSED ONAIR COOLEDONLY
GRN/YEL
BLK
BLK
WHT
BLK
GRN/YEL
M
BLK
BLK
BLK
BLK
BLK
NOTES:
1) STANDBY TEMP. PROBE IS NOT PRESENT ON
MODELS WITHOUT THE STANDBY MODE FEATURE
BLK
COPELAND COMPRESSOR BRISTOL COMPRESSOR
GRN/YEL
GRN/YEL
GRN/YEL
GRN/YEL
GRN/YEL
GRN/YEL
GRN/YEL
BLACK
BLUE
BLACK
T1
L2
T2
L1
CP
L2
BEATER MOTOR
GE/RBC BEATER MOTOR WIRING
NOTE: FOR CCWLE - BLUE INTERNAL ON #1,YELLOW INTERNAL ON #2
BLUE
T3 L3
J12 OR PURPLE INTERNAL
T1 OR BLUE INTERNAL
T8 OR RED INTERNAL
J9 OR BLACK INTERNAL A
14
5
T4 OR YELLOW INTERNAL
2
1
2
5
4
S
R
LINE
RELAY
START CAPACITOR
C
INTERNAL OVERLOAD
RUN CAPACITOR
SCHEMATIC WIRING DIAGRAM - CSR
1
2
5
4
C
S
R
LINE
RELAY RUN
CAP.
START CAP.
COMPRESSOR
TERMINAL
COVER
ABOVE ELECTRICAL DIAGRAM SHOWS WIRING NECESSARY
TO HOOK UP A COMPRESSOR USING A START AND RUN
CAPACITOR (CSR) WITH A RELAY.
WHITE
BROWN
BLACK
BROWN
36880-2
EQUIPMENT
GROUND
BLEED RESISTOR
BLUE
RSCMIX COMPRESSORCURRENT RELAYMSI13OVERLOAD
START
MAIN
1
2
5
4
S
R
LINE
RELAY
START CAPACITOR
C
INTERNAL OVERLOAD
RUN CAPACITOR
SCHEMATIC WIRING DIAGRAM - CSR
1
2
5
4
C
S
R
LINE
RELAY RUN
CAP.
START CAP.
COMPRESSOR
TERMINAL
COVER
ABOVE ELECTRICAL DIAGRAM SHOWS WIRING NECESSARY
TO HOOK UP A COMPRESSOR USING A START AND RUN
CAPACITOR (CSR) WITH A RELAY.
WHITE
BROWN
BLACK
BROWN
052396-1
EQUIPMENT
GROUND
BLEED RESISTOR
WHITE(120 VOLTS; 220V-50Hz)
BLACK(230 VOLTS)
BLACK
BLUE
CONTROL
ENCLOSURE(S)
M1M
BLK BLK
PRESSURE
SW.
WHT
4
3
2
YEL
WHT
BLU
RED
BLK
PUMP ROTATION
AS VIEWED
FROM FRONT
OVLD.
RESET
MIX
PUMP
24VAC
26
48
37
BLK

MIX PUMP

FIG. 3

ALTERNATE WIRING
DIAGRAM
MOTOR
CCW LINE
YEL
WHT
BLK
OVLD.
RELAY
3
24
BLK
WHT
L1
L2 DR N

FIG. 2

FIG. 1

(SEE FIG. 4)
(SEE FIG. 2)
(SEE FIG. 1)
(SEE FIG. 4)
(SEE FIG. 4)
BBNO

DOOR INTERLOCK

SWITCH

FIG. 4

C0MWIRE #11 OFRIBBON CABLEBLK WHT
1
2
3
4
T8
T1
T7
T4
T5
BLACK
BLUE
BLACK
T1
L2
T2
L1
CP
L2
BEATER MOTOR
OVERLOAD
LEESON BEATER MOTOR WIRING
STEPS:
1) DISCONNECT WIRE T7 FROM TERMINAL 3
2) SPLICE BLUE WIRE AS SHOWN
1
2
4
6
BLACK
BLUE
BLACK
T1
L2
T2
L1
CP
L2
BEATER MOTOR
OVERLOAD
MAGNETEK BEATER MOTOR WIRING
STEPS:
1) REMOVE BROWN JUMPER FROM BETWEEN TERMINAL #1 TO TERMINAL #5
2) MOVE BLUE INTERNAL (FROM MOTOR MAIN WINDING)
FROM TERMINAL #5 TO TERMINAL #1.
NOTE: FOR CCWLE - BLUE INTERNAL ON #1, YELLOW INTERNAL ON #6
BLUE INTERNAL
3
5
ORANGE INTERNAL
RED INTERNAL
YELLOW INTERNAL
BLACK INTERNAL
BLUE
BLUE
BEATER MOTOR
CONTACTOR
BEATER MOTOR
CONTACTOR
L2
BEATER MOTOR
CONTACTOR
BEATER MOTOR
CONTACTOR
WHT
WHT
BLK
BLK
BLK/WHT
BLK/WHT