10 Model C300 NPImportant: Tothe Operator
Control SwitchThe control switch is located at the top left c orner of
the control channel. When placed in the ON position,
allows SLUSHTECH operation.
Liquid Crystal DisplayThe Liquid Crystal Display (LCD) is located on the
front control panel. The LCD is used to show the
current operating mode of the freezing cylinders.
The LCD also indicates whether there is enough
syrup, CO2, and water being supplied to the freezer.
If an error in the machine operation occurs, a
warning tone will sound and the word “FAULT” will
flash on the third line of the display.
Operational Mode DisplayThe displays below illustrate the Operational Mode
Displays. This information appears on the LCD
during normal operation.
When the unit is plugged into the wall receptacle
and the control switch is in the ON position, this
screen appears.
SAFETY TIMEOUT
ANY KEY ABORT
This display will remain on the LCD for 60 seconds
unless a key is pressed. If any key is pressed (or 60
seconds passes) then the next screen appears.
OFF MODE OFF
OK SYRUP OK
CO2-OK WATER-OK
Note: Syrup, CO2and water are satisfied .
Pressing the AUTO (- ->) keys on both sides of the
unit will display this screen.
AUTO MODE AUTO
OK SYRUP OK
CO2-OK WATER-OK
Line 1 indicates the operating mode for each
freezing cylinder.
Line 2 indicates the status of the syrup systems in
each freezing cylinder. As long as syrup is available,
the word “OK” will appear on the LCD. When the
syrup supply is insufficient, the word “OUT ” will flash
on the LCD. The same rules apply to the fourth line
which indicates the status of the CO2and the H2O.
The third line of this display is a fault indicator. I f an
error in machine operation occurs, the word
“FAULT” will be displayed on the LCD.
BEATER MODE BEATER
OUT SYRUP OUT
- -FAULT- - - -FAULT- -
CO2-OUT H2O-OUT
Operator Menu DisplayThe OPERATOR MENU is used to enter into the
operating screens. To access the OPERAT OR
MENU, simply press the MENU (SEL) key. The
cursor will flash under the letter “A”, indicating t hat
this is screen A. To select a different sc reen, use the
AUTO (- ->) and OFF (<- -) keys to move the cursor
to the desired screen selection and press the MENU
(SEL) key.
OPERATOR MENU
ABCDEFGHI
EXIT MENU
<- - --> SEL