22 Model C300 NPOperating Procedures
Press the MENU (SEL) key.
Move the cursor under the word “SANITIZE ” by
pressing the OFF (<- -)key.
RINSE / SANITIZE
RINSE SANITIZE EXIT
-----
<- - --> SEL
Step 7
Pressing the MENU (SEL) key will give you the
option for sanitizing the left freezing cylinder. Move
the cursor under the word “YES”. Pressing the
MENU (SEL) key at this time will start the f low of
sanitizing solution into the left freezing cylinder.
SANITIZE
LEFT SIDE YES NO
---
<- - --> SEL
Repeat Steps 6 - 7 for the right sid e freezing
cylinder.
SANITIZE
RIGHT SIDE YES NO
---
<- - --> SEL
Step 8
Open the prime plugs. Place an empty pail under the
door spouts. When sanitizing solution fills the
freezing cylinders approximately 2/3 full, close t he
prime plugs.
Step 9
Continue filling the freezing cylinders with sanitizing
solution until the solution purges out of the vent at
the top of the mix tank, and begins draining into the
front drip tray. Press the OFF (<- -) key.
Step 10
Press the BEATER (- - -) key. Agitate the solution in
the freezing cylinders for five minutes.
Figure 26
Step 11
With a pail beneath the door spouts, open the draw
valves and drain all the solution from the freezing
cylinders. Press the OFF (<- -) key and close the
draw valves.
Figure 27
Step 12
Disconnect the syrup connectors in the sanitizing
solution.