12 Model C300 NPImportant: Tothe Operator
6. SYRUP PRESS LOW - When the syrup out
indicator displays a lack of syrup, the unit will
enter a HOLD mode. At this time, no
refrigeration or product flow from the flow
control will be allowed. Only the beater will
operate. When the syrup is satisfied, the unit
will refill the product tank, and then
automatically return to the AUTO mode. T he
fault message and the warning tone will clear.
FAULT DESCRIPTION
L: NOFAULT FOUND
R: SYRUPPRESS LOW
CLR +++ SEL
7. CO2PRESSURE LOW - When the CO2out
indicator displays a lack of CO2, a 60 second
internal timer will start. If the CO2is not
replenished at the end of the 60 seconds, both
freezing cylinders will shut down and this fault
message will appear. Replenish the CO2and
the fault message and warning tone will clear.
FAULT DESCRIPTION
L: CO2PRESSURE LOW
R: CO2PRESSURE LOW
CLR +++ SEL
8. H2O PRESSURE LOW - When the water out
indicator displays a lack of water, a 60 second
internal timer will start. If the water is not
replenished at the end of the 60 seconds, all
freezing cylinders will shut down and this fault
message will appear. Replenish the water and
the fault message and warning tone will clear.
FAULT DESCRIPTION
L: H2OPRESSURE LOW
R: H2OPRESSURE LOW
CLR +++ SEL
9. BRL NOT COOLING - A freezing cylinder
check has been established for the AUTO
mode of operation. If a freezing cylinder enters
the AUTO mode, the control will check product
temperature. After five minutes, it will again
check product temperature. If product
temperature does not drop in that five minute
time span, the freezing cylinder will shut down
and this message will appear on the fault
screen. For this check to be valid, the product
temperature must be above 40_F(4.4_C).
FAULT DESCRIPTION
L: BARRELNOT COOLING
R: NOFAULT FOUND
CLR +++ SEL
10. BRL TEMP 2 HIGH - A maximum allowable
product temperature has been established to
prevent product from excessive heating. If the
product exceeds 120_F(49_C) temperature for
any reason (in any mode of operation), the
entire unit shuts down.
FAULT DESCRIPTION
L: BARRELTEMP 2 HIGH
R: NOFAULT FOUND
CLR +++ SEL
Faults, when corrected, are cleared from t he fault
description screen, with the following exception:
BRL NOT COOLING. This fault requires the
operator to press the OFF (<- -) k ey (when in the
FAULT DESCRIPTION screen) in order for the fault
to discontinue.
To see if there is more than one fault in either
freezing cylinder, press the PRIME (+ + +) key. To
return to the OPERATORMENU, press the MENU
(SEL) key once. To return to the Main Screen, use
the AUTO (- ->) key to cycle to MENU ITEM A, then
press the MENU (SEL) key.