13
Model C300 NP Important: To the Operator
Screen C is SET CLOCK.UsetheAUTO(-->)and
OFF (<- -) keys to place the cursor under the
element to be set (hours, minutes, month, day, or
year). Usethe PRIME (+++) and BEATER (- - -)
keys to increment or decrement the value. Press the
MENU (SEL) key to advance to the Daylight Saving
Time screen.
Note: The clock is programmed with military time.
SET CLOCK
14:30 10/25/06
<-- -->+++ --- SEL
This screen will appear if an invalid date is entered.
(example: If the date entered exceeds the days of
that month.)
SET CLOCK
14:30 02/31/07
INVALID DATE SEL
This screen allows the Daylight Saving Time
options. If the Daylight Saving Time option is
enabled, then the time will be advanced by one hour
at 2:00 a.m. on the first Sunday in April, and will be
retarded by one hour at 2:00 a.m. on the last
Sunday in October.
DAYLIGHT SAVING TIME
ENABLE DISABLE
<- - --> SEL
Screen D is MANUAL DEFROST. This screen
allows the operator to manually defrost the left side
of the unit.
Place the cursor under YES, press the MENU (SEL)
key, and the command will be executed.
MANUAL DEFROST
LEFT SIDE YES NO
<- - --> SEL
Repeat the procedure for the right side of the unit.
MANUAL DEFROST
RIGHT SIDE YES NO
<- - --> SEL
Note: Only one side of the unit may be placed in
the DEFROST modeat a given time. Attempting to
place a side of the unit into DEFROST while the
other side is defrosting, will result in the following
screen:
ALREADY IN DEFROST
Press the MENU (SEL) key to return the unit to the
OPERATOR MENU.
Screen E is SYSTEM INFORMATION.Itconsists
of 6 display features.
The first feature indicates the softw are version.
SYSTEM INFORMATION
C300 CONTROL UVC2
VERSION 1.03 SEL
The second feature indicates the bill of material
number and the serial number. It also indicates if the
unit is equipped with a water pressure switch.
B.O.M.C30027C000
S/N K0000000
WITH H20 PRESS SW SEL
The third feature indicates the version number of t he
language and text.
SYSTEM INFORMATION
LANGUAGE
VERSION 1.09 ENGLISH 446 SEL